J059--SOURCES SOUGHT NOTICE SWITCHGEAR MAINTENANCE TESTING SERVICES BALTIMORE VA MEDICAL CENTER 36C24526Q0196
- Country
- United States
- Published
- December 29, 2025
- Deadline
- January 12, 2026
Description
{"description":"SUMMARY:\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. The Baltimore VA Medical Center is in need of a qualified contractor for NETA Maintenance Testing of a GE PowerVac 15KV Switchgear Lineup. Scope of work on the last few pages. \nInterested & Capable Responses: Must respond with the following information.\nNCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Baltimore VA Medical Center.\nPlease respond to this RFI/Sources Sought 36C24526Q0196 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nResponses must be submitted by 10:00 AM (ET) NLT 01-12-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov \nRespond: 36C24526Q0196 Sources Sought Notice | Company Name\nThis request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.).\n\n\n\n\n \nScope of Work: \n\nNETA Maintenance Testing of GE PowerVac 15KV Switchgear Lineup\nLocation: Department of Veterans Affairs, VA Hospital Baltimore, Maryland\n1. SCOPE\nThe purpose of this Performance Work Statement (PWS) is to define the requirements for the Contractor to perform NETA Maintenance Testing and inspection services on the GE PowerVac 15KV Switchgear Lineup located at the VA Hospital in Baltimore, Maryland.\nThe contractor shall provide all labor, supervision, materials, test instruments, and equipment necessary to perform the work in accordance with the latest edition of ANSI/NETA Maintenance Testing Specifications (MTS), applicable ANSI, IEEE, NFPA, and manufacturer s recommendations.\nAll testing shall be performed de-energized and coordinated with the VA to ensure minimal disruption to facility operations.\n2.0 APPLICABLE DOCUMENTS AND STANDARDS\nThe following documents and standards, or the latest revisions thereof, shall apply to the work performed under this PWS:\nANSI/NETA MTS Standard for Maintenance Testing Specifications for Electrical Power Equipment and Systems\nNFPA 70 National Electrical Code (NEC)\nNFPA 70E Standard for Electrical Safety in the Workplace\nOSHA 29 CFR 1910 Subpart S Electrical Safety Requirements\nManufacturer s published operation and maintenance manuals\n3.0 EQUIPMENT TO BE TESTED\nThe GE PowerVac 15KV Switchgear lineup consists of the following sections:\nBGE Utility Main #13708\n(4) 51 mechanical relays\n(1) 86-2 lockout relay section\n(3) 87B differential relays\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nBGE Utility Main #13709\n(4) 51 mechanical relays\n(1) 86-2 lockout relay section\n(3) 87B differential relays\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nTie Breaker (13709 to 7835)\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nTie Breaker (13708 to 7835)\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\n(2) Metering compartment sections\n(1) PT/CT compartment for 13708 section\n(1) PT/CT compartment for 13709 section\n(7) Feeder breaker sections, each with (3) 50/51 mechanical relays and (1) 51GS mechanical relay\n(1) Ground and test device section\n(1) Section equipped for breaker spare\n4.0 REQUIREMENTS AND PERFORMANCE TASKS\n4.1 Switchgear and Bus Testing\nThe contractor shall:\nPerform visual and mechanical inspection of all switchgear sections.\nClean and torque all accessible bolted electrical connections.\nConduct insulation resistance testing (phase-to-phase and phase-to-ground).\nPerform contact resistance testing of main bus and breaker stabs.\n4.2 Circuit Breaker Testing (15KV PowerVac)\nThe contractor shall:\nConduct visual and mechanical inspection.\nPerform contact resistance and insulation resistance testing.\nPerform vacuum bottle integrity testing.\nConduct primary current injection testing to verify trip operation.\nPerform mechanical timing and operation testing.\n4.3 Protective Relay Testing (Electromechanical Relays)\nThe contractor shall:\nCalibrate and functionally test all 51, 50/51, 51GS, 27, 27X, 60, 62, 86, and 87B relays per manufacturer tolerances.\nVerify control circuit continuity, wiring integrity, and tripping path functionality.\n4.4 PT/CT and Metering Testing\nThe contractor shall:\nPerform ratio, polarity, and insulation resistance testing.\nPerform burden and excitation testing where applicable.\n4.5 Grounding Verification\nThe contractor shall:\nPerform visual inspection of all grounding buses, connections, and hardware.\nVerify ground continuity and ground resistance.\n4.6 Additional Functional Testing\nThe contractor shall:\nFunctionally test all mechanical and electrical interlocks and safety devices.\nVerify trip coordination as found and as left. \n5.0 DELIVERABLES\nThe contractor shall submit the following deliverables:\nField Test Data Sheets for all tested equipment.\nCalibration Reports for all relays and devices.\nSummary Report indicating pass/fail status against NETA criteria.\nDeficiency List of any equipment not meeting performance standards.\nFinal Comprehensive Test Report in both PDF and hard copy format.\nAll reports shall include test values, instrument serial numbers, calibration dates, and technician signatures.\n6.0 PERFORMANCE STANDARDS\nTask\nPerformance Standard\nAcceptable Quality Level (AQL)\nPerform testing per NETA MTS and manufacturer standards\n100% compliance\nNo deviations\nSubmit completed test report within 10 business days of testing\n100% on time\nNo late submissions\nProvide qualified NETA-certified technicians\n100% compliance\nNo unqualified personnel\nMaintain safety compliance (NFPA 70E/OSHA)\n100% compliance\nNo safety violations\n7.0 GOVERNMENT RESPONSIBILITIES\nThe VA Hospital shall:\nProvide access to the equipment and ensure system de-energization during testing.\nCoordinate and schedule required electrical outages.\nProvide existing drawings, single-line diagrams, and relay settings where available.\n8.0 CONTRACTOR RESPONSIBILITIES\nThe contractor shall:\nProvide all necessary test equipment, tools, and safety gear.\nEnsure all instruments are calibrated and traceable to NIST standards.\nProvide qualified NETA-certified or equivalent personnel to perform testing.\nComply with all facility safety and security procedures.\n9.0 EXCLUSIONS\nThe following items are specifically excluded from the scope of this contract:\nRepairs or replacement of defective components.\nChanges to relay settings or updates to coordination studies.\nTemporary power generation or load bank services.\nEnergized infrared thermography.\nCleaning beyond standard wipe-down.\nCivil, structural, or rigging work related to equipment access.\n10.0 SAFETY\nAll work shall comply with applicable VA safety regulations, OSHA standards, and NFPA 70E.\nPersonnel shall wear appropriate arc flash PPE, and all lockout/tagout procedures shall be followed before testing begins.\nSCHEDULE\nThe contractor shall coordinate the testing schedule with VA Engineering and Facilities Management staff.\nA proposed testing plan and timeline shall be submitted for approval no later than 10 business days prior to mobilization.\nQUALITY ASSURANCE\nAll test procedures and data shall conform to the NETA Maintenance Testing Specifications.\nThe contractor s Quality Control Representative shall verify that all results are reviewed, signed, and certified prior to submission.\n\n"} Solicitation Number: 36C24526Q0196 Type: Sources Sought Base Type: Sources Sought NAICS: 238210 Classification Code: J059 Response Deadline: 2026-01-12T10:00:00-06:00 Office Address: LINTHICUM, MD Place of Performance: Baltimore, Maryland, 21201 POC: Bill Pratt, Billie.Pratt@va.gov, 410-642-2411 {"description":"SUMMARY:\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. The Baltimore VA Medical Center is in need of a qualified contractor for NETA Maintenance Testing of a GE PowerVac 15KV Switchgear Lineup. Scope of work on the last few pages. \nInterested & Capable Responses: Must respond with the following information.\nNCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Baltimore VA Medical Center.\nPlease respond to this RFI/Sources Sought 36C24526Q0196 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nResponses must be submitted by 10:00 AM (ET) NLT 01-12-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov \nRespond: 36C24526Q0196 Sources Sought Notice | Company Name\nThis request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.).\n\n\n\n\n \nScope of Work: \n\nNETA Maintenance Testing of GE PowerVac 15KV Switchgear Lineup\nLocation: Department of Veterans Affairs, VA Hospital Baltimore, Maryland\n1. SCOPE\nThe purpose of this Performance Work Statement (PWS) is to define the requirements for the Contractor to perform NETA Maintenance Testing and inspection services on the GE PowerVac 15KV Switchgear Lineup located at the VA Hospital in Baltimore, Maryland.\nThe contractor shall provide all labor, supervision, materials, test instruments, and equipment necessary to perform the work in accordance with the latest edition of ANSI/NETA Maintenance Testing Specifications (MTS), applicable ANSI, IEEE, NFPA, and manufacturer s recommendations.\nAll testing shall be performed de-energized and coordinated with the VA to ensure minimal disruption to facility operations.\n2.0 APPLICABLE DOCUMENTS AND STANDARDS\nThe following documents and standards, or the latest revisions thereof, shall apply to the work performed under this PWS:\nANSI/NETA MTS Standard for Maintenance Testing Specifications for Electrical Power Equipment and Systems\nNFPA 70 National Electrical Code (NEC)\nNFPA 70E Standard for Electrical Safety in the Workplace\nOSHA 29 CFR 1910 Subpart S Electrical Safety Requirements\nManufacturer s published operation and maintenance manuals\n3.0 EQUIPMENT TO BE TESTED\nThe GE PowerVac 15KV Switchgear lineup consists of the following sections:\nBGE Utility Main #13708\n(4) 51 mechanical relays\n(1) 86-2 lockout relay section\n(3) 87B differential relays\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nBGE Utility Main #13709\n(4) 51 mechanical relays\n(1) 86-2 lockout relay section\n(3) 87B differential relays\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nTie Breaker (13709 to 7835)\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\nTie Breaker (13708 to 7835)\n(1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay\n(2) Metering compartment sections\n(1) PT/CT compartment for 13708 section\n(1) PT/CT compartment for 13709 section\n(7) Feeder breaker sections, each with (3) 50/51 mechanical relays and (1) 51GS mechanical relay\n(1) Ground and test device section\n(1) Section equipped for breaker spare\n4.0 REQUIREMENTS AND PERFORMANCE TASKS\n4.1 Switchgear and Bus Testing\nThe contractor shall:\nPerform visual and mechanical inspection of all switchgear sections.\nClean and torque all accessible bolted electrical connections.\nConduct insulation resistance testing (phase-to-phase and phase-to-ground).\nPerform contact resistance testing of main bus and breaker stabs.\n4.2 Circuit Breaker Testing (15KV PowerVac)\nThe contractor shall:\nConduct visual and mechanical inspection.\nPerform contact resistance and insulation resistance testing.\nPerform vacuum bottle integrity testing.\nConduct primary current injection testing to verify trip operation.\nPerform mechanical timing and operation testing.\n4.3 Protective Relay Testing (Electromechanical Relays)\nThe contractor shall:\nCalibrate and functionally test all 51, 50/51, 51GS, 27, 27X, 60, 62, 86, and 87B relays per manufacturer tolerances.\nVerify control circuit continuity, wiring integrity, and tripping path functionality.\n4.4 PT/CT and Metering Testing\nThe contractor shall:\nPerform ratio, polarity, and insulation resistance testing.\nPerform burden and excitation testing where applicable.\n4.5 Grounding Verification\nThe contractor shall:\nPerform visual inspection of all grounding buses, connections, and hardware.\nVerify ground continuity and ground resistance.\n4.6 Additional Functional Testing\nThe contractor shall:\nFunctionally test all mechanical and electrical interlocks and safety devices.\nVerify trip coordination as found and as left. \n5.0 DELIVERABLES\nThe contractor shall submit the following deliverables:\nField Test Data Sheets for all tested equipment.\nCalibration Reports for all relays and devices.\nSummary Report indicating pass/fail status against NETA criteria.\nDeficiency List of any equipment not meeting performance standards.\nFinal Comprehensive Test Report in both PDF and hard copy format.\nAll reports shall include test values, instrument serial numbers, calibration dates, and technician signatures.\n6.0 PERFORMANCE STANDARDS\nTask\nPerformance Standard\nAcceptable Quality Level (AQL)\nPerform testing per NETA MTS and manufacturer standards\n100% compliance\nNo deviations\nSubmit completed test report within 10 business days of testing\n100% on time\nNo late submissions\nProvide qualified NETA-certified technicians\n100% compliance\nNo unqualified personnel\nMaintain safety compliance (NFPA 70E/OSHA)\n100% compliance\nNo safety violations\n7.0 GOVERNMENT RESPONSIBILITIES\nThe VA Hospital shall:\nProvide access to the equipment and ensure system de-energization during testing.\nCoordinate and schedule required electrical outages.\nProvide existing drawings, single-line diagrams, and relay settings where available.\n8.0 CONTRACTOR RESPONSIBILITIES\nThe contractor shall:\nProvide all necessary test equipment, tools, and safety gear.\nEnsure all instruments are calibrated and traceable to NIST standards.\nProvide qualified NETA-certified or equivalent personnel to perform testing.\nComply with all facility safety and security procedures.\n9.0 EXCLUSIONS\nThe following items are specifically excluded from the scope of this contract:\nRepairs or replacement of defective components.\nChanges to relay settings or updates to coordination studies.\nTemporary power generation or load bank services.\nEnergized infrared thermography.\nCleaning beyond standard wipe-down.\nCivil, structural, or rigging work related to equipment access.\n10.0 SAFETY\nAll work shall comply with applicable VA safety regulations, OSHA standards, and NFPA 70E.\nPersonnel shall wear appropriate arc flash PPE, and all lockout/tagout procedures shall be followed before testing begins.\nSCHEDULE\nThe contractor shall coordinate the testing schedule with VA Engineering and Facilities Management staff.\nA proposed testing plan and timeline shall be submitted for approval no later than 10 business days prior to mobilization.\nQUALITY ASSURANCE\nAll test procedures and data shall conform to the NETA Maintenance Testing Specifications.\nThe contractor s Quality Control Representative shall verify that all results are reviewed, signed, and certified prior to submission.\n\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.