Back to search
SAM.govNotice 9a6c2d80c9c74cc7bc2f35d489bafbf9

J042--Fire and Electric Doors PM and Repairs

Country
United States
Published
March 5, 2026
Deadline
March 16, 2026

Description

{"description":" UPDATE - March 5, 2026: AMENDMENT 0002 ISSUED \n\n The purpose of Amendment 0002 is to extend the deadline for receipt of offers and notify offerors of a forthcoming amendment. \n\n \n\t New Proposal Due Date: Thursday, March 12, 2026, at 1:00 PM PST. \n\t Forthcoming Amendment 0003: The Government is currently finalizing its responses to timely vendor Requests for Information (RFIs). A subsequent amendment (Amendment 0003) will be published prior to the new proposal due date. Amendment 0003 will include the consolidated RFI responses, updates to the Price/Cost Schedule, and a revised Statement of Work (SOW) modifying the door inventory. Offerors are advised to wait for the release of Amendment 0003 before finalizing their pricing and technical volumes. \n \n\n Title: Inspection, Maintenance, and Repair of Automatic and Fire-Rated Doors – VA Northern California Health Care System (VANCHCS) \n\n Description: The Department of Veterans Affairs, Network Contracting Office (NCO) 21, has a requirement for a contractor to provide all labor, materials, tools, equipment, supervision, and transportation necessary to perform comprehensive inspection, preventive maintenance (PM), testing, and repair services for automatic and fire-rated pedestrian door systems. \n\n Scope of Work: The Contractor shall maintain all automatic sliding and swinging doors, low- and high-energy operators, motion/presence sensors, control access systems, and fire-rated pedestrian doors. Services shall ensure equipment functions safely, reliably, and in compliance with NFPA 80, NFPA 101, California Building/Fire Codes, and ANSI/BHMA A156.10 and A156.19 standards. \n\n Key Requirements: \n\n \n\t Preventive Maintenance: Quarterly PM for automatic doors and annual inspection/functional testing for fire-rated doors and automatic door openers. \n\t Emergency & Corrective Repair: The Contractor shall provide unscheduled maintenance and repairs upon request. Emergency after-hours service must be available 24/7 with a response time not exceeding six (6) hours. Routine corrective maintenance during business hours requires a response time of four (4) hours. \n\t Parts: Repairs requiring parts must be completed within 48 hours, subject to availability. All parts used must be Original Equipment Manufacturer (OEM) or approved equal. \n\t Certifications: Technicians must be American Association of Automatic Door Manufacturers (AAADM) certified or possess equivalent certification and experience. \n\t Reporting: Detailed service reports and Fire Door Inspection Reports (compliant with NFPA 80) are required within 14 calendar days of service. \n \n\n Place of Performance: Services are required at seven (7) locations within the VANCHCS: \n\n \n\t Sacramento VA Medical Center (Mather, CA) \n\t McClellan VA Outpatient Clinic (McClellan, CA) \n\t Mare Island Outpatient Clinic (Vallejo, CA) \n\t Travis Air Force Base – David Grant Medical Center (Fairfield, CA) – Note: DBIDS access required 14 days in advance \n\t Travis Air Force Base – Sequoia Clinic (Fairfield, CA) \n\t Stockton Community Based Outpatient Clinic (French Camp, CA) \n\t Martinez Outpatient Clinic (Martinez, CA) \n \n\n Contract Type: Firm-Fixed-Price with Contract Line Items (CLINs) for unscheduled repairs. \n"} Solicitation Number: 36C26126Q0302RFQ Type: Solicitation Base Type: Solicitation NAICS: 811310 Classification Code: J042 Response Deadline: 2026-03-16T13:00:00-07:00 Office Address: MATHER, CA Place of Performance: Martinez, California, 94553 POC: Edwin Rivera, edwin.rivera@va.gov, Contracting Officer {"description":" UPDATE - March 5, 2026: AMENDMENT 0002 ISSUED \n\n The purpose of Amendment 0002 is to extend the deadline for receipt of offers and notify offerors of a forthcoming amendment. \n\n \n\t New Proposal Due Date: Thursday, March 12, 2026, at 1:00 PM PST. \n\t Forthcoming Amendment 0003: The Government is currently finalizing its responses to timely vendor Requests for Information (RFIs). A subsequent amendment (Amendment 0003) will be published prior to the new proposal due date. Amendment 0003 will include the consolidated RFI responses, updates to the Price/Cost Schedule, and a revised Statement of Work (SOW) modifying the door inventory. Offerors are advised to wait for the release of Amendment 0003 before finalizing their pricing and technical volumes. \n \n\n Title: Inspection, Maintenance, and Repair of Automatic and Fire-Rated Doors – VA Northern California Health Care System (VANCHCS) \n\n Description: The Department of Veterans Affairs, Network Contracting Office (NCO) 21, has a requirement for a contractor to provide all labor, materials, tools, equipment, supervision, and transportation necessary to perform comprehensive inspection, preventive maintenance (PM), testing, and repair services for automatic and fire-rated pedestrian door systems. \n\n Scope of Work: The Contractor shall maintain all automatic sliding and swinging doors, low- and high-energy operators, motion/presence sensors, control access systems, and fire-rated pedestrian doors. Services shall ensure equipment functions safely, reliably, and in compliance with NFPA 80, NFPA 101, California Building/Fire Codes, and ANSI/BHMA A156.10 and A156.19 standards. \n\n Key Requirements: \n\n \n\t Preventive Maintenance: Quarterly PM for automatic doors and annual inspection/functional testing for fire-rated doors and automatic door openers. \n\t Emergency & Corrective Repair: The Contractor shall provide unscheduled maintenance and repairs upon request. Emergency after-hours service must be available 24/7 with a response time not exceeding six (6) hours. Routine corrective maintenance during business hours requires a response time of four (4) hours. \n\t Parts: Repairs requiring parts must be completed within 48 hours, subject to availability. All parts used must be Original Equipment Manufacturer (OEM) or approved equal. \n\t Certifications: Technicians must be American Association of Automatic Door Manufacturers (AAADM) certified or possess equivalent certification and experience. \n\t Reporting: Detailed service reports and Fire Door Inspection Reports (compliant with NFPA 80) are required within 14 calendar days of service. \n \n\n Place of Performance: Services are required at seven (7) locations within the VANCHCS: \n\n \n\t Sacramento VA Medical Center (Mather, CA) \n\t McClellan VA Outpatient Clinic (McClellan, CA) \n\t Mare Island Outpatient Clinic (Vallejo, CA) \n\t Travis Air Force Base – David Grant Medical Center (Fairfield, CA) – Note: DBIDS access required 14 days in advance \n\t Travis Air Force Base – Sequoia Clinic (Fairfield, CA) \n\t Stockton Community Based Outpatient Clinic (French Camp, CA) \n\t Martinez Outpatient Clinic (Martinez, CA) \n \n\n Contract Type: Firm-Fixed-Price with Contract Line Items (CLINs) for unscheduled repairs. \n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
J042--Fire and Electric Doors PM and Repairs tender | Tenqual