Back to search
SAM.govNotice 6d0b048b35ed44118552174aaa46b2b6

6515--Dose Calibrator Brand Name or Equal

Country
United States
Published
January 20, 2026
Deadline
January 27, 2026

Description

{"description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n \nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service-Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a Brand Name or Equal Dose Calibrator to the Edward Hines, Jr. VA Hospital 5000 South 5th Avenue Hines, IL 60141-5000.\n \n\nBrand Name \n\n\n\n\nDESCRIPTION OF SUPPLIES\nManufacturer\nManufacturer Part No\nQTY\nCRC-55TW with a CRC-55TR DOS CALIBRATOR AND CAPRAC-T WIPE TEST COUNTER\nMirion Technologies (Capintec)\nB-5130-2216\n1\n\n\nGeneral Requirements:\n\nSalient Characteristics: (Equal)\n \n8 in. color display or larger\nMust have USB/PC Communications\nMust have the ability to upgrade software via USB or flash drive\nUSB printer capability\nChamber plug and play capability\n28 programmable nuclide keys\nBuilt-in dose calibration, quality control and self diagnostics\nMust have over 80 nuclides in memory\nMust have automatic chamber QC including linearity\nHard copy records of data available from optional printer\nMust have 256 channel MCA with detailed spectrum for identification analysis\nWell counter for wipe tests\nUser-definable protocols for wipe testing\nAutomated well QC including Chi-Square and MDA\nManual and automatic ROI\nMust include a pre-set key for F-18 measurements\nAutomated Linearity and Geometry testing\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nUIE number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\n \nSubmit responses to the Contracting Specialist, Waymon McNeal, at Waymon.McNealjr@va.gov no later than 3:00 PM (Central Standard Time), 27 January 2026.\n \n36C25226Q0217 Dose Calibrator shall be referenced on all correspondence regarding this announcement.\n \n \nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n \nThe NAICS Code 339112 Surgical and Medical Instrument Manufacturing is applicable to this acquisition; the size standard is 1000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.\n \n \n\n"} Solicitation Number: 36C25226Q0217 Type: Sources Sought Base Type: Sources Sought NAICS: 339112 Classification Code: 6515 Response Deadline: 2026-01-27T15:00:00-06:00 Office Address: MILWAUKEE, WI Place of Performance: Hines, Illinois, 60141-5000 POC: waymon.mcnealjr@va.gov, waymon.mcnealjr@va.gov, 4148444800 {"description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n \nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service-Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a Brand Name or Equal Dose Calibrator to the Edward Hines, Jr. VA Hospital 5000 South 5th Avenue Hines, IL 60141-5000.\n \n\nBrand Name \n\n\n\n\nDESCRIPTION OF SUPPLIES\nManufacturer\nManufacturer Part No\nQTY\nCRC-55TW with a CRC-55TR DOS CALIBRATOR AND CAPRAC-T WIPE TEST COUNTER\nMirion Technologies (Capintec)\nB-5130-2216\n1\n\n\nGeneral Requirements:\n\nSalient Characteristics: (Equal)\n \n8 in. color display or larger\nMust have USB/PC Communications\nMust have the ability to upgrade software via USB or flash drive\nUSB printer capability\nChamber plug and play capability\n28 programmable nuclide keys\nBuilt-in dose calibration, quality control and self diagnostics\nMust have over 80 nuclides in memory\nMust have automatic chamber QC including linearity\nHard copy records of data available from optional printer\nMust have 256 channel MCA with detailed spectrum for identification analysis\nWell counter for wipe tests\nUser-definable protocols for wipe testing\nAutomated well QC including Chi-Square and MDA\nManual and automatic ROI\nMust include a pre-set key for F-18 measurements\nAutomated Linearity and Geometry testing\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nUIE number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\n \nSubmit responses to the Contracting Specialist, Waymon McNeal, at Waymon.McNealjr@va.gov no later than 3:00 PM (Central Standard Time), 27 January 2026.\n \n36C25226Q0217 Dose Calibrator shall be referenced on all correspondence regarding this announcement.\n \n \nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n \nThe NAICS Code 339112 Surgical and Medical Instrument Manufacturing is applicable to this acquisition; the size standard is 1000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.\n \n \n\n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
6515--Dose Calibrator Brand Name or Equal tender | Tenqual