Y1DZ--PN: 636-26-305 Correct Parking Garage Safety Deficiencies (OM) 2237: 636-26-3-5297-0001
- Country
- United States
- Published
- February 11, 2026
- Deadline
- April 30, 2026
Description
{"description":"This is a Pre-Solicitation Notice regarding project: 636-23-301, 636-26-305 Correct Parking Garage Safety Deficiencies at the VA Health Care System Central Plains / Omaha, Nebraska. The Department of Veterans Affairs, Network Contracting Office 23 (NCO 23), is preparing to issue a Two-Phase solicitation for a Design-Build contract for this project.\nNote: This is a Pre-Solicitation Notice only, the Solicitation will not be posted for at least 15 days from the date of this notice. This is NOT a request for proposal.\nEstimated SOLICITATION DATE (Phase I): on or about 02/26/2026\nEstimated AWARD DATE: 06/16/2026\nSET-ASIDE: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\nNAICS: 236220, Commercial and Institutional Building Construction $45.0 Million\nPROJECT MAGNITUDE: Between $2,000,000 and $5,000,000.\nTHIS IS A TOTAL 100% SERVICE-DISABLED VETERAN OWNED SMALL BUSINESS (SDVOSB) SET-ASIDE. In accordance with Public Law 109-461 and VAAR 819.7003 (b), bidders must be registered, certified, and listed in the SBA certification database at  https://veterans.certify.sba.gov/ as a SDVOSB/VOSB. Only bids from verified SDVOSB s at SBA certification database at the time of proposal submission shall be deemed responsive. All non-responsive bids shall be rejected and ineligible for award.\n\nProject Overview\nThe project will require the selected contractor to provide all design, labor, materials, tools and equipment, and construction services necessary for the design and construction of the project: 636-26-305 Correct Parking Garage Safety Deficiencies as defined by the Performance of Work Statement (PWS).\nThe Two-Phase Design-Build solicitation and evaluation process shall be conducted in accordance with Revolutionary FAR Overhaul (RFO) 36.101-2 -Two-Phase Design-Build Selection Procedures. The issued Request for Proposal (RFP) shall set forth the requirements for responding to Phase I of the solicitation, as well as all technical evaluation factors and sub-factors for both Phase I and Phase II.\nAt the closing date of the Phase I Solicitation, the government shall evaluate responsive proposals received in response to Phase I of the solicitation. No more than four (4) contractors will move forward to Phase II. Only those successful firms selected as a result of Phase I evaluations will be requested to submit technical and pricing proposals for Phase II. Phase II proposals shall be evaluated in accordance with the Phase II Evaluation Process.\nBackground. \nThis project will require a Design-Build Team to develop and install a dry-pipe fire suppression system and jump prevention barriers in the parking garage at the Omaha Veterans Affairs Medical Center. The design shall incorporate best practices and methods and comply with Veterans Health Administration design guidelines. Barriers shall be consistent with the architecture of the parking garage and shall be mounted to and removable from existing barriers for reinstallation following potential future modifications to the garage.\n\nSuccessful offeror will be an integrated Design-Build team including Licensed Architects, Engineers, and Construction specialties to complete the scope of work. At minimum, the Design Team will include experienced Architectural, Civil, Structural, Mechanical/Plumbing, Electrical, Fire Protection, and Environmental design professionals. All architects and engineers must be professionally licensed in their field of practice. The fire protection engineer must be qualified and provide all services in accordance with the VA Project Fire Protection Engineer Qualifications and Scope of Services document. Separate independent peer review is required for the Life-Safety and Fire Protection elements of this project and shall be provided by the Design-Build Contractor as within the scope of this Performance of Work Statement (PWS).\n\nNOTE: \nThis Performance of Work Statement (PWS) will refer to the collective Design-Build Team, which includes both Design and Construction, for performance requirements pertaining to the entire scope of work. Where appropriate, Design Team or Construction Team may be used for specificity. All elements of design, construction, and post-construction are included in this PWS.\n\nAnticipated Period of Performance: The contract Period of Performance for the design phase shall be 100 calendar days from the Notice of Award. Period of Performance for total design and construction is 280 calendar days from Contract Award. The time stated for completion includes final cleanup of the premises, as-builts and closeout documents.\n\nAll prospective bidders must have a Unique Entity Identifier (UEI) and must be registered and active in the SAM database (http://www.sam.gov). All prospective bidders must complete electronic online Representations and Certifications within SAM. The eventual awardee shall also have on file a current Department of Labor VETS4212 Federal Contractor Reporting filing at https://www.dol.gov/agencies/vets/programs/vets4212 (if applicable).\n\n\n"} Solicitation Number: 36C26326R0030 Type: Presolicitation Base Type: Presolicitation NAICS: 236220 Classification Code: Y1DZ Response Deadline: 2026-04-30T12:00:00-05:00 Office Address: Saint Paul, MN Place of Performance: Omaha, NE, 68105 POC: Derek Fore, derek.fore@va.gov, 651-293-3032 {"description":"This is a Pre-Solicitation Notice regarding project: 636-23-301, 636-26-305 Correct Parking Garage Safety Deficiencies at the VA Health Care System Central Plains / Omaha, Nebraska. The Department of Veterans Affairs, Network Contracting Office 23 (NCO 23), is preparing to issue a Two-Phase solicitation for a Design-Build contract for this project.\nNote: This is a Pre-Solicitation Notice only, the Solicitation will not be posted for at least 15 days from the date of this notice. This is NOT a request for proposal.\nEstimated SOLICITATION DATE (Phase I): on or about 02/26/2026\nEstimated AWARD DATE: 06/16/2026\nSET-ASIDE: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\nNAICS: 236220, Commercial and Institutional Building Construction $45.0 Million\nPROJECT MAGNITUDE: Between $2,000,000 and $5,000,000.\nTHIS IS A TOTAL 100% SERVICE-DISABLED VETERAN OWNED SMALL BUSINESS (SDVOSB) SET-ASIDE. In accordance with Public Law 109-461 and VAAR 819.7003 (b), bidders must be registered, certified, and listed in the SBA certification database at  https://veterans.certify.sba.gov/ as a SDVOSB/VOSB. Only bids from verified SDVOSB s at SBA certification database at the time of proposal submission shall be deemed responsive. All non-responsive bids shall be rejected and ineligible for award.\n\nProject Overview\nThe project will require the selected contractor to provide all design, labor, materials, tools and equipment, and construction services necessary for the design and construction of the project: 636-26-305 Correct Parking Garage Safety Deficiencies as defined by the Performance of Work Statement (PWS).\nThe Two-Phase Design-Build solicitation and evaluation process shall be conducted in accordance with Revolutionary FAR Overhaul (RFO) 36.101-2 -Two-Phase Design-Build Selection Procedures. The issued Request for Proposal (RFP) shall set forth the requirements for responding to Phase I of the solicitation, as well as all technical evaluation factors and sub-factors for both Phase I and Phase II.\nAt the closing date of the Phase I Solicitation, the government shall evaluate responsive proposals received in response to Phase I of the solicitation. No more than four (4) contractors will move forward to Phase II. Only those successful firms selected as a result of Phase I evaluations will be requested to submit technical and pricing proposals for Phase II. Phase II proposals shall be evaluated in accordance with the Phase II Evaluation Process.\nBackground. \nThis project will require a Design-Build Team to develop and install a dry-pipe fire suppression system and jump prevention barriers in the parking garage at the Omaha Veterans Affairs Medical Center. The design shall incorporate best practices and methods and comply with Veterans Health Administration design guidelines. Barriers shall be consistent with the architecture of the parking garage and shall be mounted to and removable from existing barriers for reinstallation following potential future modifications to the garage.\n\nSuccessful offeror will be an integrated Design-Build team including Licensed Architects, Engineers, and Construction specialties to complete the scope of work. At minimum, the Design Team will include experienced Architectural, Civil, Structural, Mechanical/Plumbing, Electrical, Fire Protection, and Environmental design professionals. All architects and engineers must be professionally licensed in their field of practice. The fire protection engineer must be qualified and provide all services in accordance with the VA Project Fire Protection Engineer Qualifications and Scope of Services document. Separate independent peer review is required for the Life-Safety and Fire Protection elements of this project and shall be provided by the Design-Build Contractor as within the scope of this Performance of Work Statement (PWS).\n\nNOTE: \nThis Performance of Work Statement (PWS) will refer to the collective Design-Build Team, which includes both Design and Construction, for performance requirements pertaining to the entire scope of work. Where appropriate, Design Team or Construction Team may be used for specificity. All elements of design, construction, and post-construction are included in this PWS.\n\nAnticipated Period of Performance: The contract Period of Performance for the design phase shall be 100 calendar days from the Notice of Award. Period of Performance for total design and construction is 280 calendar days from Contract Award. The time stated for completion includes final cleanup of the premises, as-builts and closeout documents.\n\nAll prospective bidders must have a Unique Entity Identifier (UEI) and must be registered and active in the SAM database (http://www.sam.gov). All prospective bidders must complete electronic online Representations and Certifications within SAM. The eventual awardee shall also have on file a current Department of Labor VETS4212 Federal Contractor Reporting filing at https://www.dol.gov/agencies/vets/programs/vets4212 (if applicable).\n\n\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.