{"description":" This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit. \n\n \n\n The replacement needs to be compatible with the following specifications: \n\n Outdoor Unit (Condenser): \n\n Nominal Capacity: 20 TON (240,000 BTU/h) \n\n Voltage: 208/230V – 3 Phase – 60HZ \n\n Refrigerant TYPE: R-22 \n\n Compressors: 2-Stage (Dual) Scroll Compressors \n\n Fans: 2 \n\n Efficiency: Up to 11.0 EER / 14.8 IEER \n\n Dimensions: ~50.4” H x 103.4” W x 54.3” D \n\n Weight: 1133lbs \n\n \n\n Inside Unit (Air Handler): \n\n Nominal Capacity: 20 TON (240,000 BTU/h) \n\n Fan Motor Horsepower: 3HP \n\n Nominal Air Flow: 8000 CFM \n\n Electrical: 208/230 Volt, 3-Phrase, 60Hz \n\n Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin) \n\n \n\n \n\n Commercial Heat Element Kit \n\n For Air Handler Unit: 20 TON \n\n Voltage: 240Volts – 3 Phase – 60HZ \n\n 240 Volts, 3 Phrase \n\n Heating Capacity 19.1W \n\n Total Amps: 46 AMPS \n\n \n\n The Statement Of Need and pictures of the current unit are attached for reference. \n\n Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice. \n\n We kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST . \n\n \n"} Solicitation Number: FA3016FY2620TONAC Type: Presolicitation Base Type: Presolicitation NAICS: 423730 Classification Code: 4120 Response Deadline: 2026-02-20T16:00:00-06:00 Office Address: JBSA LACKLAND, TX Place of Performance: San Antonio, Texas POC: Ernest Sutton, ernest.sutton@us.af.mil POC: Erika Turner, erika.turner.1@us.af.mil {"description":" This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit. \n\n \n\n The replacement needs to be compatible with the following specifications: \n\n Outdoor Unit (Condenser): \n\n Nominal Capacity: 20 TON (240,000 BTU/h) \n\n Voltage: 208/230V – 3 Phase – 60HZ \n\n Refrigerant TYPE: R-22 \n\n Compressors: 2-Stage (Dual) Scroll Compressors \n\n Fans: 2 \n\n Efficiency: Up to 11.0 EER / 14.8 IEER \n\n Dimensions: ~50.4” H x 103.4” W x 54.3” D \n\n Weight: 1133lbs \n\n \n\n Inside Unit (Air Handler): \n\n Nominal Capacity: 20 TON (240,000 BTU/h) \n\n Fan Motor Horsepower: 3HP \n\n Nominal Air Flow: 8000 CFM \n\n Electrical: 208/230 Volt, 3-Phrase, 60Hz \n\n Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin) \n\n \n\n \n\n Commercial Heat Element Kit \n\n For Air Handler Unit: 20 TON \n\n Voltage: 240Volts – 3 Phase – 60HZ \n\n 240 Volts, 3 Phrase \n\n Heating Capacity 19.1W \n\n Total Amps: 46 AMPS \n\n \n\n The Statement Of Need and pictures of the current unit are attached for reference. \n\n Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice. \n\n We kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST . \n\n \n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.