6515--Portable Sleep Monitoring System
- Country
- United States
- Published
- December 3, 2025
- Deadline
- December 11, 2025
Description
{"description":"\n\n\n\n\n\nPittsburgh Healthcare System, University Drive C, Pittsburgh, PA 15420, is seeking potential sources capable of providing 20 new portable sleep monitoring systems for monitoring patient sleep patterns to determine the severity of sleep apnea for diagnosis and treatment in accordance with the Draft Statement of Need (SON) below.\n\nPlease include the following information in your response: \nCompany name\nAddress\nContact person name, phone number and email address\nUEI #\nBusiness size/classification/type (i.e. 8a, Hubzone, SDVOSB, VOSB, etc.)\nIs equipment available on FSS Contract. If so, Equipment and Contract # of items that are on schedule\nNAICS: 334510\nSize Standard: 1250 Employees\nPlease answer the following questions:\n1. If you are unable to provide the name brand, please provide the alternative model and country of origin that meets all salient characteristics.\n2. Are you the manufacturer, distributor, or equivalent solution to the above items? If not, can you provide additional information, as shown below? This confirms compliance with the nonmanufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\n3. If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is changed, assembled, or modified.\n4. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, Point of Contact, and size status (if available).\n5. General pricing of your products/solutions is encouraged. Pricing will be used for market research only, and it will not be used to evaluate for any type of award.\n6. Please submit your capabilities regarding the salient characteristics detailed above and any information about alternative items to establish capabilities for planning purposes.\n7. Please review salient characteristics/statement of need (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n\nResponses to this Sources Sought Notice shall be submitted directly via email to jefferson.mann@va.gov. Responses that only include generic marketing material and do not provide for capability to meet requirements may not be considered. Responses must be received no later than 12:00 pm (noon) ET, 12/11/2025. No solicitation document is available at this time. This notice is simply for Market Research Purposes Only. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The VA will not reimburse any potential contractors for any costs associated with this Sources Sought Notice.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nStatement of Need\nSCOPE:\nThe Sleep Department at the VA Pittsburgh Healthcare System (VAPHS) is requesting the purchase of 20 new portable sleep monitoring systems. The monitoring devices are necessary for monitoring patient sleep patterns to determine the severity of sleep apnea for diagnosis and treatment. The Watch-PAT300 with Digital RESBP (Central Plus) Kit meets all requirements as a reference for this brand name or equal requirement.\n\nSleep apnea is associated with several health complications such as heart failure, strokes, and depression to name just a few. Proper diagnosis and treatment of sleep apnea have shown to improve overall patient health, as there are numerous factors that contribute to sleep apnea which can only be identified by recording patient sleep patterns. \n\nGENERAL REQUIREMENTS:\nContractor shall provide 20 reusable portable sleep monitoring units.\nSpecifications set forth in this statement of need are minimum specifications and shall not be construed as limiting the overall quality, quantity, or performance of the instrument. \nThe offerer shall meet or exceed the minimum requirements and shall be held responsible for the performance and overall quality of the requested instrument during the instrument s warranty period.\nThe instruments, based upon the specifications requested, shall be the newest and the most current model. A refurbishment is not acceptable. \nThe vendor/distributor and/or the manufacturer must provide all necessary procedure manuals, Maintenance Manuals, troubleshooting manuals and operator manuals. \n\nBRAND NAME OR EQUAL REQUIRED SALIENT CHARACTERISTICS:\nName Brand Product for Reference:\nWatchPAT300 (Part AC3000315) with Central Plus Add-on Kit with RESBP (Part AC2110701)\n\nMust be able to monitor:\nApnea/Hyponea per hour (AHI)\nApnea/Hyponea per hour (Central AHI)\nApnea Episodes\nSnoring and Body Position\nOxygen and Heart Rate\nSleep Stages\nSnore and Body Position Sensor that detects respiratory effort\nAbility to automatically calculate AHI and RDI using the patient s True Sleep Time\nProvide information on sleep staging including sleep efficiency, sleep latency and REM latency \nDetects REM related sleep apnea with REM and non-REM apnea-hypopnea index (AHI)\nIntegrates for full operational functioning and automatic reporting with the VA Somnoware Sleep System\nVA Technical Reference Model (TRM) approved prior to quote submission\nPeripheral Arterial Tonometry (PAT) technology to detect changes in the body's vascular tone, sleep stages, and body movements\nProvide multi-night study feature\nBuilt-in self-diagnostic procedure to ensure device is operating properly prior to patient testing\nThe data recording device must be small enough to be worn on the wrist\nMust be able to be cleaned with 70% ethyl alcohol or isopropyl alcohol (IPA) \n\nDELIVERY:\nAll equipment deliveries must be coordinated with the Biomedical department prior to delivery. Failure to do so may result in the return of the equipment at vendor cost. \nLocation:\nVA Pittsburgh Healthcare System\nUniversity Drive C\nPittsburgh, PA 15240\n\n"} Solicitation Number: 36C24426Q0131 Type: Sources Sought Base Type: Sources Sought NAICS: 334510 Classification Code: 6515 Response Deadline: 2025-12-11T12:00:00-05:00 Office Address: PITTSBURGH, PA Place of Performance: Pittsburgh, PA, 15240 POC: Jeff Mann, jefferson.mann@va.gov, 717-202-5456 {"description":"\n\n\n\n\n\nPittsburgh Healthcare System, University Drive C, Pittsburgh, PA 15420, is seeking potential sources capable of providing 20 new portable sleep monitoring systems for monitoring patient sleep patterns to determine the severity of sleep apnea for diagnosis and treatment in accordance with the Draft Statement of Need (SON) below.\n\nPlease include the following information in your response: \nCompany name\nAddress\nContact person name, phone number and email address\nUEI #\nBusiness size/classification/type (i.e. 8a, Hubzone, SDVOSB, VOSB, etc.)\nIs equipment available on FSS Contract. If so, Equipment and Contract # of items that are on schedule\nNAICS: 334510\nSize Standard: 1250 Employees\nPlease answer the following questions:\n1. If you are unable to provide the name brand, please provide the alternative model and country of origin that meets all salient characteristics.\n2. Are you the manufacturer, distributor, or equivalent solution to the above items? If not, can you provide additional information, as shown below? This confirms compliance with the nonmanufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\n3. If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is changed, assembled, or modified.\n4. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, Point of Contact, and size status (if available).\n5. General pricing of your products/solutions is encouraged. Pricing will be used for market research only, and it will not be used to evaluate for any type of award.\n6. Please submit your capabilities regarding the salient characteristics detailed above and any information about alternative items to establish capabilities for planning purposes.\n7. Please review salient characteristics/statement of need (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n\nResponses to this Sources Sought Notice shall be submitted directly via email to jefferson.mann@va.gov. Responses that only include generic marketing material and do not provide for capability to meet requirements may not be considered. Responses must be received no later than 12:00 pm (noon) ET, 12/11/2025. No solicitation document is available at this time. This notice is simply for Market Research Purposes Only. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The VA will not reimburse any potential contractors for any costs associated with this Sources Sought Notice.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nStatement of Need\nSCOPE:\nThe Sleep Department at the VA Pittsburgh Healthcare System (VAPHS) is requesting the purchase of 20 new portable sleep monitoring systems. The monitoring devices are necessary for monitoring patient sleep patterns to determine the severity of sleep apnea for diagnosis and treatment. The Watch-PAT300 with Digital RESBP (Central Plus) Kit meets all requirements as a reference for this brand name or equal requirement.\n\nSleep apnea is associated with several health complications such as heart failure, strokes, and depression to name just a few. Proper diagnosis and treatment of sleep apnea have shown to improve overall patient health, as there are numerous factors that contribute to sleep apnea which can only be identified by recording patient sleep patterns. \n\nGENERAL REQUIREMENTS:\nContractor shall provide 20 reusable portable sleep monitoring units.\nSpecifications set forth in this statement of need are minimum specifications and shall not be construed as limiting the overall quality, quantity, or performance of the instrument. \nThe offerer shall meet or exceed the minimum requirements and shall be held responsible for the performance and overall quality of the requested instrument during the instrument s warranty period.\nThe instruments, based upon the specifications requested, shall be the newest and the most current model. A refurbishment is not acceptable. \nThe vendor/distributor and/or the manufacturer must provide all necessary procedure manuals, Maintenance Manuals, troubleshooting manuals and operator manuals. \n\nBRAND NAME OR EQUAL REQUIRED SALIENT CHARACTERISTICS:\nName Brand Product for Reference:\nWatchPAT300 (Part AC3000315) with Central Plus Add-on Kit with RESBP (Part AC2110701)\n\nMust be able to monitor:\nApnea/Hyponea per hour (AHI)\nApnea/Hyponea per hour (Central AHI)\nApnea Episodes\nSnoring and Body Position\nOxygen and Heart Rate\nSleep Stages\nSnore and Body Position Sensor that detects respiratory effort\nAbility to automatically calculate AHI and RDI using the patient s True Sleep Time\nProvide information on sleep staging including sleep efficiency, sleep latency and REM latency \nDetects REM related sleep apnea with REM and non-REM apnea-hypopnea index (AHI)\nIntegrates for full operational functioning and automatic reporting with the VA Somnoware Sleep System\nVA Technical Reference Model (TRM) approved prior to quote submission\nPeripheral Arterial Tonometry (PAT) technology to detect changes in the body's vascular tone, sleep stages, and body movements\nProvide multi-night study feature\nBuilt-in self-diagnostic procedure to ensure device is operating properly prior to patient testing\nThe data recording device must be small enough to be worn on the wrist\nMust be able to be cleaned with 70% ethyl alcohol or isopropyl alcohol (IPA) \n\nDELIVERY:\nAll equipment deliveries must be coordinated with the Biomedical department prior to delivery. Failure to do so may result in the return of the equipment at vendor cost. \nLocation:\nVA Pittsburgh Healthcare System\nUniversity Drive C\nPittsburgh, PA 15240\n\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.