Back to search
SAM.govNotice 4a670ed8c4c44ec8b5dc8bb1067d457a

USCGC Penobscot Bay Water Mist Suppression System

Country
United States
Published
December 1, 2025
Deadline
December 5, 2025

Description

{"description":" STATEMENT OF WORK \n\n \n\n CGC PENOBSCOT BAY OPFAC: 17507 LOCATION: Bayonne, NJ \n\n EQUIPMENT: Hi-Fog Water Mist Fire Suppression System \n\n COMPONENT AFFECTED: 5YR and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified \n\n MPC: R-A-13380, R-M-13373, R-C-14526 \n\n Contractor must be HI-FOG certified Technician . Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. \n\n Replacement Parts to be included in 5-Year Annual Inspection: \n\n 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2REGULATOR (A20079.1) 2 - FILTER WATER FILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETYVALVES (M-0010165) 2 - SVM20 DNV VALVE REBUILD KITS (V14020), Jockey Pump \n\n Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. \n\n POP: 08DEC25-12DEC25 \n\n LOCATION/POC: \n\n Ricciardi, Vincent CWO-2 USCG CGC PENOBSCOT BAY (USA) Vincent.Ricciardi@uscg.mil \n\n Address: \n\n CGC Penobscot Bay (WTGB-107) \n\n 85 Port Terminal Blvd. Slip 2 \n\n Bayonne NJ. 07002 \n\n 252-619-6669 \n"} Solicitation Number: 70Z08526Q0000870-1 Type: Combined Synopsis/Solicitation Base Type: Combined Synopsis/Solicitation NAICS: 336611 Classification Code: J020 Response Deadline: 2025-12-05T08:00:00-08:00 Office Address: ALAMEDA, CA Place of Performance: Bayonne, New Jersey, 07002 POC: Justin Wooldridge, justin.r.wooldridge2@uscg.mil, 2068205327 POC: Lindsay Mongiovi, lindsay.n.mongiovi@uscg.mil, 5716086752 {"description":" STATEMENT OF WORK \n\n \n\n CGC PENOBSCOT BAY OPFAC: 17507 LOCATION: Bayonne, NJ \n\n EQUIPMENT: Hi-Fog Water Mist Fire Suppression System \n\n COMPONENT AFFECTED: 5YR and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified \n\n MPC: R-A-13380, R-M-13373, R-C-14526 \n\n Contractor must be HI-FOG certified Technician . Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. \n\n Replacement Parts to be included in 5-Year Annual Inspection: \n\n 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2REGULATOR (A20079.1) 2 - FILTER WATER FILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETYVALVES (M-0010165) 2 - SVM20 DNV VALVE REBUILD KITS (V14020), Jockey Pump \n\n Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. \n\n POP: 08DEC25-12DEC25 \n\n LOCATION/POC: \n\n Ricciardi, Vincent CWO-2 USCG CGC PENOBSCOT BAY (USA) Vincent.Ricciardi@uscg.mil \n\n Address: \n\n CGC Penobscot Bay (WTGB-107) \n\n 85 Port Terminal Blvd. Slip 2 \n\n Bayonne NJ. 07002 \n\n 252-619-6669 \n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
USCGC Penobscot Bay Water Mist Suppression System tender | Tenqual