C1DA--528A6-26-604 Bath Dry Sprinklers

Country
United States
Published
February 20, 2026
Deadline
March 4, 2026

Description

{"description":"This amendment to the previous sources sought notice serves to answer RFIs and provide a scope of work for this project:\n\nRFI#1: Can you confirm whether the estimated construction magnitude of $2,000,000 $5,000,000 applies individually to each project (Bath and Canandaigua), or represents the combined magnitude for both sites?\nConstruction magnitude of $2,000,000 $5,000,000 applies individually to each site/project.\nRFI#2: Are final design documents required to be signed and sealed by a Professional Engineer licensed in the State of New York, or will equivalent licensure in fire protection engineering from another state be acceptable? \nProfessional Engineer licensed, with demonstrated familiarity of standards and regulations of the State of New York and federal standards and regulations.\nPer SOW: Personnel Required for Design Effort \nCertified and Registered Fire Design Professional with demonstrated familiarity with\nNew York State and Federal standards and regulations\nDeveloping systems that are easily maintained and serviceable in early 20th century buildings\nCertified and Registered Architect with demonstrated familiarity with\nNew York State and Federal historical preservation\nWorking in patientcare and treatment areas\nRFI#3: Will phased construction or temporary fire protection provisions be required to maintain sprinkler coverage during replacement within occupied healthcare facilities?\nYes\nRFI#4: Will the design team be responsible for performing full facility site surveys and system verification, or will existing as-built documentation be provided and considered reliable for design development?\nYes \nRFI#5: Both solicitations note to use a Section E Cover Sheet and Section F Cover Sheet. Is this a form in addition to the Section E Resume template page? I can t seem to find a cover page anywhere online.\nThis just advises firms to use the Section E template ahead of each individual Resume and a Section F template ahead of each individual example to better organize and separate individual examples. \n"} Solicitation Number: 36C24226R0073 Type: Sources Sought Base Type: Sources Sought NAICS: 541330 Classification Code: C1DA Response Deadline: 2026-03-04T12:00:00-05:00 Office Address: ALBANY, NY Place of Performance: Bath, New York, 14823 POC: Devan Bertch, Devan.Bertch@va.gov, 716-698-6459 {"description":"This amendment to the previous sources sought notice serves to answer RFIs and provide a scope of work for this project:\n\nRFI#1: Can you confirm whether the estimated construction magnitude of $2,000,000 $5,000,000 applies individually to each project (Bath and Canandaigua), or represents the combined magnitude for both sites?\nConstruction magnitude of $2,000,000 $5,000,000 applies individually to each site/project.\nRFI#2: Are final design documents required to be signed and sealed by a Professional Engineer licensed in the State of New York, or will equivalent licensure in fire protection engineering from another state be acceptable? \nProfessional Engineer licensed, with demonstrated familiarity of standards and regulations of the State of New York and federal standards and regulations.\nPer SOW: Personnel Required for Design Effort \nCertified and Registered Fire Design Professional with demonstrated familiarity with\nNew York State and Federal standards and regulations\nDeveloping systems that are easily maintained and serviceable in early 20th century buildings\nCertified and Registered Architect with demonstrated familiarity with\nNew York State and Federal historical preservation\nWorking in patientcare and treatment areas\nRFI#3: Will phased construction or temporary fire protection provisions be required to maintain sprinkler coverage during replacement within occupied healthcare facilities?\nYes\nRFI#4: Will the design team be responsible for performing full facility site surveys and system verification, or will existing as-built documentation be provided and considered reliable for design development?\nYes \nRFI#5: Both solicitations note to use a Section E Cover Sheet and Section F Cover Sheet. Is this a form in addition to the Section E Resume template page? I can t seem to find a cover page anywhere online.\nThis just advises firms to use the Section E template ahead of each individual Resume and a Section F template ahead of each individual example to better organize and separate individual examples. \n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
C1DA--528A6-26-604 Bath Dry Sprinklers tender | Tenqual