Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System
- Country
- United States
- Published
- December 12, 2025
- Deadline
- December 22, 2025
Description
{"description":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System \n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810 \nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78. \n\nExisting Conditions \nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts. \nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff. \n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon\n"} Solicitation Number: 36C24226B0016 Type: Solicitation Base Type: Solicitation NAICS: 238210 Classification Code: Y1DA Response Deadline: 2025-12-22T12:30:00-05:00 Office Address: ALBANY, NY POC: Devan Bertch, Devan.Bertch@va.gov {"description":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System \n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810 \nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78. \n\nExisting Conditions \nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts. \nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff. \n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.