J042--Fire and Electric Doors PM and Repairs
- Country
- United States
- Published
- February 4, 2026
- Deadline
- March 6, 2026
Description
{"description":" Title: Inspection, Maintenance, and Repair of Automatic and Fire-Rated Doors – VA Northern California Health Care System (VANCHCS) \n\n Description: The Department of Veterans Affairs, Network Contracting Office (NCO) 21, has a requirement for a contractor to provide all labor, materials, tools, equipment, supervision, and transportation necessary to perform comprehensive inspection, preventive maintenance (PM), testing, and repair services for automatic and fire-rated pedestrian door systems,. \n\n Scope of Work: The Contractor shall maintain all automatic sliding and swinging doors, low- and high-energy operators, motion/presence sensors, control access systems, and fire-rated pedestrian doors,. Services shall ensure equipment functions safely, reliably, and in compliance with NFPA 80, NFPA 101, California Building/Fire Codes, and ANSI/BHMA A156.10 and A156.19 standards. \n\n Key Requirements: \n\n • Preventive Maintenance: Quarterly PM for automatic doors and annual inspection/functional testing for fire-rated doors and automatic door openers-. \n\n • Emergency & Corrective Repair: The Contractor shall provide unscheduled maintenance and repairs upon request. Emergency after-hours service must be available 24/7 with a response time not exceeding six (6) hours. Routine corrective maintenance during business hours requires a response time of four (4) hours. \n\n • Parts: Repairs requiring parts must be completed within 48 hours, subject to availability. All parts used must be Original Equipment Manufacturer (OEM) or approved equal. \n\n • Certifications: Technicians must be American Association of Automatic Door Manufacturers (AAADM) certified or possess equivalent certification and experience. \n\n • Reporting: Detailed service reports and Fire Door Inspection Reports (compliant with NFPA 80) are required within 14 calendar days of service,. \n\n Place of Performance: Services are required at seven (7) locations within the VANCHCS: \n\n 1. Sacramento VA Medical Center (Mather, CA) \n\n 2. McClellan VA Outpatient Clinic (McClellan, CA) \n\n 3. Mare Island Outpatient Clinic (Vallejo, CA) \n\n 4. Travis Air Force Base – David Grant Medical Center (Fairfield, CA) – Note: DBIDS access required 14 days in advance \n\n 5. Travis Air Force Base – Sequoia Clinic (Fairfield, CA) \n\n 6. Stockton Community Based Outpatient Clinic (French Camp, CA) \n\n 7. Martinez Outpatient Clinic (Martinez, CA) \n\n Contract Type: Firm-Fixed-Price with Contract Line Items (CLINs) for unscheduled repairs. \n"} Solicitation Number: 36C26126Q0302RFQ Type: Solicitation Base Type: Solicitation NAICS: 811310 Classification Code: J042 Response Deadline: 2026-03-06T12:00:00-08:00 Office Address: MATHER, CA Place of Performance: Martinez, California, 94553 POC: Edwin Rivera, edwin.rivera@va.gov, Contracting Officer {"description":" Title: Inspection, Maintenance, and Repair of Automatic and Fire-Rated Doors – VA Northern California Health Care System (VANCHCS) \n\n Description: The Department of Veterans Affairs, Network Contracting Office (NCO) 21, has a requirement for a contractor to provide all labor, materials, tools, equipment, supervision, and transportation necessary to perform comprehensive inspection, preventive maintenance (PM), testing, and repair services for automatic and fire-rated pedestrian door systems,. \n\n Scope of Work: The Contractor shall maintain all automatic sliding and swinging doors, low- and high-energy operators, motion/presence sensors, control access systems, and fire-rated pedestrian doors,. Services shall ensure equipment functions safely, reliably, and in compliance with NFPA 80, NFPA 101, California Building/Fire Codes, and ANSI/BHMA A156.10 and A156.19 standards. \n\n Key Requirements: \n\n • Preventive Maintenance: Quarterly PM for automatic doors and annual inspection/functional testing for fire-rated doors and automatic door openers-. \n\n • Emergency & Corrective Repair: The Contractor shall provide unscheduled maintenance and repairs upon request. Emergency after-hours service must be available 24/7 with a response time not exceeding six (6) hours. Routine corrective maintenance during business hours requires a response time of four (4) hours. \n\n • Parts: Repairs requiring parts must be completed within 48 hours, subject to availability. All parts used must be Original Equipment Manufacturer (OEM) or approved equal. \n\n • Certifications: Technicians must be American Association of Automatic Door Manufacturers (AAADM) certified or possess equivalent certification and experience. \n\n • Reporting: Detailed service reports and Fire Door Inspection Reports (compliant with NFPA 80) are required within 14 calendar days of service,. \n\n Place of Performance: Services are required at seven (7) locations within the VANCHCS: \n\n 1. Sacramento VA Medical Center (Mather, CA) \n\n 2. McClellan VA Outpatient Clinic (McClellan, CA) \n\n 3. Mare Island Outpatient Clinic (Vallejo, CA) \n\n 4. Travis Air Force Base – David Grant Medical Center (Fairfield, CA) – Note: DBIDS access required 14 days in advance \n\n 5. Travis Air Force Base – Sequoia Clinic (Fairfield, CA) \n\n 6. Stockton Community Based Outpatient Clinic (French Camp, CA) \n\n 7. Martinez Outpatient Clinic (Martinez, CA) \n\n Contract Type: Firm-Fixed-Price with Contract Line Items (CLINs) for unscheduled repairs. \n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.