Back to search
SAM.govNotice 96b3b6e529f24a87a07d31f0a4df3f10

J059--Siemens Apogee/HVACR Maintenance and Operation Services- Greater Los Angeles VA Healthcare System

Country
United States
Published
February 5, 2026
Deadline
February 10, 2026

Description

{"description":"RFQ Inquiries Siemens Apogee System Maintenance and Operations Services (GLA) 36C26226Q0233\nPlease provide a System Profile report from Siemens Insight to assist in estimating.\nNot available\n\nPlease provide an all points report from Siemens Insight to assist in estimating.\nNot available\nPlease provide a count of total sensors requiring calibration or verification annually per SOW (Section B.3). \nCalibration of sensors is as required knowledge of Siemens Apogee system is a must to meet this requirement.\n\nIs there a GFE parts inventory? Or is contractor responsible for stocking ALL sensors, actuators, and circuit boards from day one? \nContractor is expected to be able to procure any parts required to complete repair within 24 hours of failed report and have knowledge of items that cannot be procured quickly to have them in stock. \n\nThe Statement of Work (Section B.3) defines normal working hours as 6:00 AM 4:00 PM, Monday through Friday, but does not specify the required onsite staffing level. To ensure offerors provide pricing consistent with the Government s operational expectations, please clarify:\nDoes the Government require a dedicated, full-time onsite technician during normal working hours? \nYes we require a full-time onsite tech and 24-hour remote access to monitoring and temp/air flow adjustments as required. There must be 24 hours, 7 days a week and include holidays for remote temperature adjustments. \nWhat was the typical onsite staffing model utilized by the incumbent to successfully meet the current requirements? \n2 Staff onsite and any support staff required to meet the needs of the facility.\n\nSection 6.k states the COR may direct more frequent system checks 'as determined by the COR.' Please confirm whether COR-directed service increases beyond the minimum frequencies specified in the SOW will be handled via contract modification with equitable adjustment or are considered within the base FFP scope. \nSystem checks can be requested as COR determines for onsite personnel to complete. During normal operational hours and at no extra cost to the government.\n\nEstimate number of historical emergency callouts annually? \nDaily remote temperature adjustment and system monitoring is required. It cannot be based on average need to have availability of tech to respond to call out daily if required. \n\n"} Solicitation Number: 36C26226Q0233 Type: Solicitation Base Type: Solicitation NAICS: 561210 Classification Code: J059 Response Deadline: 2026-02-10T10:00:00-08:00 Office Address: Gilbert, AZ POC: Jennell Christofaro, jennell.christofaro@va.gov {"description":"RFQ Inquiries Siemens Apogee System Maintenance and Operations Services (GLA) 36C26226Q0233\nPlease provide a System Profile report from Siemens Insight to assist in estimating.\nNot available\n\nPlease provide an all points report from Siemens Insight to assist in estimating.\nNot available\nPlease provide a count of total sensors requiring calibration or verification annually per SOW (Section B.3). \nCalibration of sensors is as required knowledge of Siemens Apogee system is a must to meet this requirement.\n\nIs there a GFE parts inventory? Or is contractor responsible for stocking ALL sensors, actuators, and circuit boards from day one? \nContractor is expected to be able to procure any parts required to complete repair within 24 hours of failed report and have knowledge of items that cannot be procured quickly to have them in stock. \n\nThe Statement of Work (Section B.3) defines normal working hours as 6:00 AM 4:00 PM, Monday through Friday, but does not specify the required onsite staffing level. To ensure offerors provide pricing consistent with the Government s operational expectations, please clarify:\nDoes the Government require a dedicated, full-time onsite technician during normal working hours? \nYes we require a full-time onsite tech and 24-hour remote access to monitoring and temp/air flow adjustments as required. There must be 24 hours, 7 days a week and include holidays for remote temperature adjustments. \nWhat was the typical onsite staffing model utilized by the incumbent to successfully meet the current requirements? \n2 Staff onsite and any support staff required to meet the needs of the facility.\n\nSection 6.k states the COR may direct more frequent system checks 'as determined by the COR.' Please confirm whether COR-directed service increases beyond the minimum frequencies specified in the SOW will be handled via contract modification with equitable adjustment or are considered within the base FFP scope. \nSystem checks can be requested as COR determines for onsite personnel to complete. During normal operational hours and at no extra cost to the government.\n\nEstimate number of historical emergency callouts annually? \nDaily remote temperature adjustment and system monitoring is required. It cannot be based on average need to have availability of tech to respond to call out daily if required. \n\n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
J059--Siemens Apogee/HVACR Maintenance and Operation Services- Greater Los Angeles VA Healthcare System tender | Tenqual