4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS
- Country
- United States
- Published
- February 9, 2026
- Deadline
- February 17, 2026
Description
{"description":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1)\n- Organics (TOC) - typical 250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C)\n-- Flowrate: (requirement at 15°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation < 70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High\n"} Solicitation Number: 36C24626Q0335 Type: Sources Sought Base Type: Sources Sought NAICS: 333310 Classification Code: 4610 Response Deadline: 2026-02-17T10:00:00-05:00 Office Address: HAMPTON, VA POC: John P Harmsen, john.harmsen@va.gov, 757-722-7961 {"description":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1)\n- Organics (TOC) - typical 250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C)\n-- Flowrate: (requirement at 15°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation < 70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.