6685--Bath VAMC-Temperature/Humidity Monitoring equipment (VA-26-00026567)
- Country
- United States
- Published
- December 11, 2025
- Deadline
- December 18, 2025
Description
{"description":"\nStatement of Work \nTemperature and Humidity Monitoring\nPROJECT NO. 528A6-24-602\n\nBackground:\nThe VA Finger Lakes Health Care System has established a requirement to use the Rotronic Temperature and Humidity monitoring system; as the system of record for the Bath VA Medical Center, located at, 76 Veterans Ave, Bath, NY 14810. \n This will ensure that Bath, Canandaigua and Rochester locations will all operate on the same system of record.\nScope:\nVendor shall provide all the required new humidity and temperature monitoring devices for purchase. \nService Requirements:\nVender shall provide new devices, quantities listed below, for the Bath VAMC. \nVendor shall provide devices as indicated in devices purchase base year \n Device Purchase - Base year: \nProvide the devices models and required shown below to be used for Bath VA Medical center. \nBrand\nQuantity \nModel \nRotronic\n66\nRMS-MLOG-T10-915 w/ probe\nRotronic\n112\nRMS-MLOG-B-915\nRotronic\n125\n915 GATEWAY\n\nHours:\nWork shall be performed Monday Friday between 8:00 am - 4:00 pm, EST or at a time\npredetermined with the Contracting Officer Representative (COR) and Vendor. \n\n"} Solicitation Number: 36C24226Q0201 Type: Presolicitation Base Type: Presolicitation NAICS: 334513 Classification Code: 6685 Response Deadline: 2025-12-18T10:00:00-05:00 Office Address: ALBANY, NY Place of Performance: Bath, NY, 14805 POC: Lorraine A Hussain, Lorraine.Hussain@va.gov {"description":"\nStatement of Work \nTemperature and Humidity Monitoring\nPROJECT NO. 528A6-24-602\n\nBackground:\nThe VA Finger Lakes Health Care System has established a requirement to use the Rotronic Temperature and Humidity monitoring system; as the system of record for the Bath VA Medical Center, located at, 76 Veterans Ave, Bath, NY 14810. \n This will ensure that Bath, Canandaigua and Rochester locations will all operate on the same system of record.\nScope:\nVendor shall provide all the required new humidity and temperature monitoring devices for purchase. \nService Requirements:\nVender shall provide new devices, quantities listed below, for the Bath VAMC. \nVendor shall provide devices as indicated in devices purchase base year \n Device Purchase - Base year: \nProvide the devices models and required shown below to be used for Bath VA Medical center. \nBrand\nQuantity \nModel \nRotronic\n66\nRMS-MLOG-T10-915 w/ probe\nRotronic\n112\nRMS-MLOG-B-915\nRotronic\n125\n915 GATEWAY\n\nHours:\nWork shall be performed Monday Friday between 8:00 am - 4:00 pm, EST or at a time\npredetermined with the Contracting Officer Representative (COR) and Vendor. \n\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.