Z2DA--Replace MRI 1.5T
- Country
- United States
- Published
- January 15, 2026
- Deadline
- January 27, 2026
Description
{"description":"It calls out fiber for the injector to the actual MRI machine. Need to know if it is Sigle Mode or Multi Mode fiber. How many strands of fiber they are needing there and the type of connectors they need on the end of the fiber. Injector has a fiber optic cable that is supplied with the purchase of the injector, so the contractor is not responsible for providing that cable. There is no additional fiber needed for the MRI machine.\nNeed to know how many data drops per location it is not called out anywhere also need to know how many data cables are being demoed. 4 drops per location and there are none that need to be demolished.\nAny other fiber on this job would need to know the same questions on that fiber as the fiber mentioned in question 1. There is no additional fiber needed for the MRI machine.\nPer point 2. of the Addendum_1_Narrative regarding Revised Door Hardware for RF Shielding Room, Specification 08 34 46, those specs do not actually pertain to RF shielding for MRI rooms. They look more like specs for acoustic rooms. Please see attached updated specifications.\n\n"} Solicitation Number: 36C24626B0001 Type: Solicitation Base Type: Solicitation NAICS: 236220 Classification Code: Z2DA Response Deadline: 2026-01-27T11:00:00-05:00 Office Address: HAMPTON, VA POC: Michael R Proctor, Michael.Proctor2@va.gov {"description":"It calls out fiber for the injector to the actual MRI machine. Need to know if it is Sigle Mode or Multi Mode fiber. How many strands of fiber they are needing there and the type of connectors they need on the end of the fiber. Injector has a fiber optic cable that is supplied with the purchase of the injector, so the contractor is not responsible for providing that cable. There is no additional fiber needed for the MRI machine.\nNeed to know how many data drops per location it is not called out anywhere also need to know how many data cables are being demoed. 4 drops per location and there are none that need to be demolished.\nAny other fiber on this job would need to know the same questions on that fiber as the fiber mentioned in question 1. There is no additional fiber needed for the MRI machine.\nPer point 2. of the Addendum_1_Narrative regarding Revised Door Hardware for RF Shielding Room, Specification 08 34 46, those specs do not actually pertain to RF shielding for MRI rooms. They look more like specs for acoustic rooms. Please see attached updated specifications.\n\n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.