J041--Preventive Maintenance and Repair Services for the HVAC Water Chillers and Air Handling Units at the VA Caribbean Healthcare System
- Country
- United States
- Published
- April 30, 2026
- Deadline
- May 4, 2026
Description
{"description":"INTRODUCTION\n\nThe Department of Veterans Affairs (VA), Network Contracting Office (NCO) 8, San Juan, Puerto Rico is issuing this sources-sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support the requirement for Preventive Maintenance and Repair Services for the HVAC Water Chillers and Air Handling Units at the VA Caribbean Healthcare System (VACHS) . The Government anticipates issuing a single award firm fixed price requirements type contract with an ordering period of five (5) years, plus a potential six (6) month extension. The intent of this notice is to identify interested sources and their respective socio-economic group and to develop the Acquisition Strategy for this requirement. \n\nResponses to this sources-sought notice/market research may be used to issue the requirement as set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), small businesses, or procured through full and open competition. \n\nDISCLAIMER\n\nThis sources-sought is for informational purposes only. This is not a Request for Quote (RFQ). It does not constitute a solicitation and shall not be construed as a commitment by the government. Do not submit pricing quotes. Proprietary information must be clearly marked and will be safeguarded accordingly. Responses in any form are not quotes, and the government is under no obligation to award a contract as a result of this announcement. No funds are available to pay for the preparation of responses to this announcement. \n\nAny information submitted by respondents to this technical description is strictly voluntary. Responses will not be returned to the responder. Not responding to this notice does not preclude participation in any future solicitation, if any is issued. If a solicitation is released, it will be synopsized through the Contracting Opportunities webpage at https://sam.gov/contracting. It is the responsibility of potential offerors to monitor the Contracting website for additional information pertaining to this requirement. Responses will be used to determine:\n\nAvailability of qualified sources and Small Business, including SDVOSB and VOSB capability. \n\nWhether to compete this requirement and the set-aside determination.\n\nMarket practices and risk considerations for final acquisition strategy.\n\nRespondents will not be notified of the results of the evaluation. \n\nBACKGROUND\n\nThe contractor shall furnish all personnel, supervision, tools, equipment, materials, transportation, and supplies necessary to perform preventive maintenance, inspections, adjustments, testing, minor repairs, emergency call backs, and selected major overhauls to maintain OEM specified performance for covered HVAC water chillers and AHUs in a healthcare environment. Requirements include compliance with applicable ASHRAE, NFPA, OSHA, EPA Section 608, VA directives, and Joint Commission Environment of Care standards.\n\nServices include, but are not limited to:\n\nPreventive Maintenance (PM) and Repair services for centrifugal, screw, and scroll chillers and AHUs. \n\n24/7 emergency support: 30 minute telephone acknowledgment; 2 hour on site response.\n\nMajor overhaul of centrifugal compressors.\n\nSheet metal/ductwork services (task order basis).\n\nSpot cooler relocation, installation, and removal (Government furnished units) during AHUs downtime.\n\nFilter supply (HEPA and V bank) (supply only).\n\nStrict health, safety, environmental, security, PPE, Hot Work permit, and infection control compliance.\n\nPlace of performance: VA Caribbean Healthcare System in San Juan, PR\n\nELIGIBILITY\n\nThe applicable North American Industry Classification System (NAICS) code for this requirement is 238220, Plumbing, Heating, and Air Conditioning Contractors, with a Small Business Size Standard of $19,000,000. The Product Service Code is J041, Maintenance, Repair, and Rebuilding of Equipment - Refrigeration, Air Conditioning, and Air Circulating Equipment. \n\nResponses to this notice shall include the company/individual name, a service capability statement, examples of similar performances for which you have provided services, System for Award Management (SAM) Unique Entity ID (UEI), address, and point of contact. Contractors shall provide their size status for the above referenced NAICS code. (i.e., small, large). Standard company brochures will not be considered a sufficient response to this Source Sought. \n\nCAPABILITY QUESTIONNAIRE\n\nCompany Information:\n\nCompany name, UEI, address, and point of contact (name, title, phone, and email).\n\nBusiness size and socio economic status under NAICS 238220 (e.g., SDVOSB, VOSB, small business, etc.)\n\nSystem for Award Management (SAM) registration status.\n\nTechnical Capability:\n\nDescribe your company s capability and experience performing comprehensive PM and repair services for centrifugal, screw, and scroll chillers, and AHUs in a hospital/healthcare environment.\n\nConfirm your ability to meet all tasks in the PWS, including:\n\nPM and repair, diagnostics, oil analysis, instrument calibration, purge system work, pump maintenance, filtration, coil cleaning (including pressure limits), fan, pulley, belt service, controls, structural components, and reporting.\n\nConfirm your ability to provide 24/7 emergency call back support with 30 minute acknowledgment and 2 hour on site response. Describe staffing, dispatch process, and coverage (in house vs. subcontractor).\n\nContractor s Qualifications:\n\nConfirm that refrigeration technicians hold valid CTRAPR licenses (Colegio de Técnicos de Refrigeración y Aire Acondicionado de Puerto Rico) or licenses recognized for practice in PR. Indicate whether these personnel will be in-house or subcontracted.\n\nConfirm that electricians hold valid CPEPR licenses (Colegio de Peritos Electricistas de Puerto Rico) or licenses recognized for practice in PR. Indicate whether these personnel will be in-house or subcontracted.\n\nConfirm qualified sheet metal/duct mechanics with documented commercial and/or institutional training and SMACNA proficiency. Indicate whether these personnel will be in-house or subcontracted.\n\nConfirm all applicable personnel have the OSHA 30 hour Construction Safety training.\n\nConfirm the availability of a licensed Mechanical Engineer (PE) for oversight only when required (e.g., design changes, Standard 170 ventilation parameters, major modifications, shutdowns affecting compliance). Indicate whether PE is in house or subcontracted.\n\nProvide examples demonstrating work in critical care areas, operating rooms, X-ray and MRI areas, pharmacy/sterile processing, or other infection control environments. Address experience with pressure relationships, air changes, filtration levels, and Joint Commission compliance.\n\nDescribe your capability to perform a major overhaul of centrifugal compressors, including specialized tools, OEM training, and test/verification procedures. Indicate if this will be performed with in-house personnel or subcontracted.\n\nConfirm ability to perform ductwork/sheet metal services adhering to SMACNA. Indicate if this will be performed with in-house personnel or subcontracted.\n\nIndicate ability to provide a trailer mounted chiller contingency support (rental, delivery, installation, operation, removal).\n\nConfirm capability to supply HEPA and V bank filters in sizes and quantities listed in the PWS (supply only). \n\nProvide an overview of your Quality Control Program to ensure your company complies with all the tasks in the PWS. \n\nIf you have an FSS contract, please provide the schedule and contract number.\n\nSUBCONTRACTING QUESTIONNAIRE (ensure your response addresses this section):\n\nDo you plan on subcontracting any task? If so, which company are you contemplating and what is its socio-economic group (i.e., SDVOSB, VOSB, small, large, etc.)?\n\nYes ___No ___ If yes, please identify which company(ies) are you considering and provide a narrative explaining the scope of the proposed subcontracting services.\n\nIdentify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.\n\nDo you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner? \n\nYes ___No ___ If yes, please identify which companies are considering a Joint Venture and the ownership of each company. \n\nPAST PERFORMANCE:\n\nProvide up to three (3) relevant contracts performed within the last five (5) years, including company and/or government agency, period of performance, contract value, scope and complexity, equipment types (centrifugal compressors, chiller plants, hospital AHUs).\n\nCOMMERCIAL PRACTICES AND COMPETITION\n\nIdentify any commercial standards or practices the Government should consider (e.g., PM frequency, cleanliness/approach temperature targets, filtration differential pressure triggers).\n\nIdentify PWS elements that may limit competition or drive high cost and suggest alternatives that still meet healthcare compliance.\n\n Interested parties are requested to submit a capabilities statement, information requested, and answers to all questions indicated above. Responses shall not exceed 10 pages. The deadline for response to this request is no later than May 4, 2026, at 10:00 AM, Puerto Rico local time. All responses under this Sources Sought Notice must be e-mailed to baryan.sierrapierluissi@va.gov.\n\nTelephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\n\nThe Government is not committed nor obligated to pay for the information provided, and no basis for claims against the Government shall arise as a result of a response to this Sources Sought.\n\n"} Solicitation Number: 36C24826Q0366 Type: Sources Sought Base Type: Sources Sought NAICS: 238220 Classification Code: J041 Response Deadline: 2026-05-04T10:00:00-03:00 Office Address: TAMPA, FL Place of Performance: San Juan, PR, 00921 POC: Baryan Sierra, baryan.sierrapierluissi@va.gov, 787-641-7582 Ext. 134983
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.