Z2DA--Replace MRI 1.5T
- Country
- United States
- Published
- January 12, 2026
- Deadline
- January 20, 2026
Description
{"description":"7. Do we know that Siemens has confirmed that there will be no active interference between the two MRI systems? We have the ability to quote magnetic compensation but need to know if it's necessary. The contractor will not be responsible for any magnetic compensation\n25. PACS: Can we the government please provide existing control panels and headend software id info, licensing info and photos? The PACS is primarily controlled by a Phillips Filter Box in the Mechanical room behind the MRI machine. The Filter Box works in conjunction with a control panel located in the control room at the front of the MRI machine (see pictures below). Once the Radiology enters pertinent information on the images, they are sent to a Mckesson System. Durham VA uses Change Healthcare Radiology Solutions 14.1, conforming to Digital Imaging in Communications In Medicine (DICOM) 3.0, as the stand for handling, storing, printing, and transmitting information in medical images. \n \n26. Finishes: Drawing A102 finish legend: All colors are listed as TBD. Can the Government please provide colors for all finishes? Blue and Green accent colors. \n"} Solicitation Number: 36C24626B0001 Type: Solicitation Base Type: Solicitation NAICS: 236220 Classification Code: Z2DA Response Deadline: 2026-01-20T11:00:00-05:00 Office Address: HAMPTON, VA POC: Michael R Proctor, Michael.Proctor2@va.gov {"description":"7. Do we know that Siemens has confirmed that there will be no active interference between the two MRI systems? We have the ability to quote magnetic compensation but need to know if it's necessary. The contractor will not be responsible for any magnetic compensation\n25. PACS: Can we the government please provide existing control panels and headend software id info, licensing info and photos? The PACS is primarily controlled by a Phillips Filter Box in the Mechanical room behind the MRI machine. The Filter Box works in conjunction with a control panel located in the control room at the front of the MRI machine (see pictures below). Once the Radiology enters pertinent information on the images, they are sent to a Mckesson System. Durham VA uses Change Healthcare Radiology Solutions 14.1, conforming to Digital Imaging in Communications In Medicine (DICOM) 3.0, as the stand for handling, storing, printing, and transmitting information in medical images. \n \n26. Finishes: Drawing A102 finish legend: All colors are listed as TBD. Can the Government please provide colors for all finishes? Blue and Green accent colors. \n"}
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.