USCG KETCHIKAN ELECTRICAL WORK

Country
United States
Published
February 19, 2026
Deadline
February 27, 2026

Description

{"description":" SEE ATTACHED SPECS/SCOPE OF WORK---- \n\n Scope of Work: Electrical Inspection and Maintenance – Floating Pier One, Base Ketchikan \n\n 1. Objective: \nProvide inspection, maintenance, and repair services for electrical systems associated with Floating Pier One, Base Ketchikan, with a focus on shore tie terminals and associated electrical lines. \n\n 2. Location: \nFloating Pier One, Base Ketchikan. Berth 5 \n\n 3. Tasks: \n\n A. Shore Tie Terminal Maintenance \n\n \n\t Inspect all shore tie terminals where vessels connect to shore power. \n\t Identify and document any damage, corrosion, moisture intrusion, or other deficiencies. \n\t Repair any identified issues to restore full functionality. \n\t Dry and seal all shore tie terminals to prevent future moisture intrusion. \n\t Test terminals for proper operation after repairs and sealing. \n\t \n \n\n B. Electrical Line Inspection and Grooming \n\n \n\t Inspect the electrical line running from the FRC Floating Pier Isolation Transfer to the shore tie terminals. \n\t Clean and groom all accessible portions of the line, removing debris, corrosion, and contaminants. \n\t Conduct a thorough inspection for physical damage, wear, or potential failure points. \n\t Perform Megger (insulation resistance) testing on the electrical lines to identify any insulation breakdowns or other potential issues. \n\t Document all findings and provide recommendations for further action if required. \n \n\n 4. Deliverables: \n\n \n\t Written inspection report detailing findings, repairs performed, and recommendations for future maintenance. \n\t Documentation of Megger test results and any corrective actions taken. \n\t Photographic evidence of before and after conditions for all work performed. \n \n\n 5. Period of Performance: \n\n \n\t Shore Tie Terminal inspection and maintenance shall be completed within two (2) weeks from award of contract. \n\t Electrical line inspection, grooming, and cleaning shall be completed within three (3) weeks from award of contract. \n\t Final written report of findings and actions written(typed) and documented shall be submitted within one (1) month from the start of the period of performance. \n \n\n 6. Safety and Compliance: \n\n \n\t All work must comply with applicable electrical codes, safety standards, and Base Ketchikan requirements. \n\t All personnel must be appropriately licensed and qualified for marine electrical work. \n \n\n Quote/Estimate: Quote or Estimate shall include materials going up to 5,000K for any repairs in the shore tie terminal box on the floating pier, but not to exceed. \n\n \n\n Question: Could you quantify the shore tie terminals and cable lengths from Isolation Transfer to each Terminal to refine labor/testing time. \n\n answer to a contractors question 1. \n\n Good Afternoon Contracting Team, \n\n The Shore tie Terminals is one box that has two plugs for shore ties. Approximate size is 4’x4’x2’ Not exact size of the box, but approximate. \n\n Approximate distance of the cable/ conduit run is 550’ plus or mins 20 feet. \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n Area of Concern: On map, it is South Float One (Berth 5 and Berth 10). \n\n \n\n \n\n Base Ketchikan POC: LT Robert Marx and CWO Russell Dever. \n\n \n\n ***contact Senior Field Contracting Officer (SFCO ) DENO STAMOS AT deno.a.stamos@uscg.mil if a site walk is required . \n\n \n\n THIS IS A COMBINED SYNOPSIS SOLICIATION. RECEIPT OF BIDS VIA EMAIL IS DUE NO LATER THAN 26 FEBRUARY 2026 AT 3:00 PM ALASKA TIME ZONE, \n\n NAICS CODE: 238210 \n FSC CODE:J059 \n\n \n"} Solicitation Number: PierOneBaseKetchikan Type: Combined Synopsis/Solicitation Base Type: Combined Synopsis/Solicitation NAICS: 238210 Classification Code: J059 Response Deadline: 2026-02-27T15:00:00-05:00 Office Address: KETCHIKAN, AK Place of Performance: Ketchikan, Alaska, 99901 POC: DENO STAMOS, deno.a.stamos@uscg.mil POC: Contracting Officer - Benjamin Reedy, benjamin.r.reedy@uscg.mil {"description":" SEE ATTACHED SPECS/SCOPE OF WORK---- \n\n Scope of Work: Electrical Inspection and Maintenance – Floating Pier One, Base Ketchikan \n\n 1. Objective: \nProvide inspection, maintenance, and repair services for electrical systems associated with Floating Pier One, Base Ketchikan, with a focus on shore tie terminals and associated electrical lines. \n\n 2. Location: \nFloating Pier One, Base Ketchikan. Berth 5 \n\n 3. Tasks: \n\n A. Shore Tie Terminal Maintenance \n\n \n\t Inspect all shore tie terminals where vessels connect to shore power. \n\t Identify and document any damage, corrosion, moisture intrusion, or other deficiencies. \n\t Repair any identified issues to restore full functionality. \n\t Dry and seal all shore tie terminals to prevent future moisture intrusion. \n\t Test terminals for proper operation after repairs and sealing. \n\t \n \n\n B. Electrical Line Inspection and Grooming \n\n \n\t Inspect the electrical line running from the FRC Floating Pier Isolation Transfer to the shore tie terminals. \n\t Clean and groom all accessible portions of the line, removing debris, corrosion, and contaminants. \n\t Conduct a thorough inspection for physical damage, wear, or potential failure points. \n\t Perform Megger (insulation resistance) testing on the electrical lines to identify any insulation breakdowns or other potential issues. \n\t Document all findings and provide recommendations for further action if required. \n \n\n 4. Deliverables: \n\n \n\t Written inspection report detailing findings, repairs performed, and recommendations for future maintenance. \n\t Documentation of Megger test results and any corrective actions taken. \n\t Photographic evidence of before and after conditions for all work performed. \n \n\n 5. Period of Performance: \n\n \n\t Shore Tie Terminal inspection and maintenance shall be completed within two (2) weeks from award of contract. \n\t Electrical line inspection, grooming, and cleaning shall be completed within three (3) weeks from award of contract. \n\t Final written report of findings and actions written(typed) and documented shall be submitted within one (1) month from the start of the period of performance. \n \n\n 6. Safety and Compliance: \n\n \n\t All work must comply with applicable electrical codes, safety standards, and Base Ketchikan requirements. \n\t All personnel must be appropriately licensed and qualified for marine electrical work. \n \n\n Quote/Estimate: Quote or Estimate shall include materials going up to 5,000K for any repairs in the shore tie terminal box on the floating pier, but not to exceed. \n\n \n\n Question: Could you quantify the shore tie terminals and cable lengths from Isolation Transfer to each Terminal to refine labor/testing time. \n\n answer to a contractors question 1. \n\n Good Afternoon Contracting Team, \n\n The Shore tie Terminals is one box that has two plugs for shore ties. Approximate size is 4’x4’x2’ Not exact size of the box, but approximate. \n\n Approximate distance of the cable/ conduit run is 550’ plus or mins 20 feet. \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n \n\n Area of Concern: On map, it is South Float One (Berth 5 and Berth 10). \n\n \n\n \n\n Base Ketchikan POC: LT Robert Marx and CWO Russell Dever. \n\n \n\n ***contact Senior Field Contracting Officer (SFCO ) DENO STAMOS AT deno.a.stamos@uscg.mil if a site walk is required . \n\n \n\n THIS IS A COMBINED SYNOPSIS SOLICIATION. RECEIPT OF BIDS VIA EMAIL IS DUE NO LATER THAN 26 FEBRUARY 2026 AT 3:00 PM ALASKA TIME ZONE, \n\n NAICS CODE: 238210 \n FSC CODE:J059 \n\n \n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
USCG KETCHIKAN ELECTRICAL WORK tender | Tenqual