DEOL ASSY ATH SHORT
- Country
- United States
- Published
- April 29, 2026
- Deadline
- April 30, 2026
Description
{"description":"ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19||||||||||||||||||||\rINSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2|||\rHIGHER-LEVEL CONTRACT QUALITY REQUIREMENT|8|||x|TBD|||||\rWIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Invoice and Receiving Report (combo) type|N/A|TBD|SPRPA1|TBD|TBD|See Schedule |TBD|N/A|N/A|TBD|N/A|N/A|N/A|N/A||\rVALUE ENGINEERING (JUN 2020)|3||||\rINTEGRITY OF UNIT PRICES (NOV 2021)|1||\rEQUAL OPPORTUNITY FOR VETERANS (JUN 2020)|4|||||\rEQUAL OPPORTUITY FOR WORKERS WITH DISABILITIES (JUN 2020)|2|||\rTRANSPORTATION OF SUPPLIES BY SEA (OCT 2024)|2|||\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11||||||||||||\rALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2025)|13||||||||||||||\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5||||||\rBUY AMERICAN--BALANCE OF PAYMENTS PROGRAM (FEB 2024)|1||\rROYALTY INFORMATION (APR 1984)|1||\rANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025)(DEVIATION 2025-O0003 AND 2025-O0004))|12|336413|1,250|||||||||||\rFACSIMILE PROPOSALS (OCT 1997)|1|215-737-7149|\rNOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PREPAREDNESS, ANDENERGY PROGRAM USE (APR 2008))|2||X|\rNo drawings are available for this Request for Quotation.\rThis Solicitation is being issued under Emergency Acquisition Flexibilities\r(EAF) formally known as SEPA\r\\\r1. SCOPE\r1.1 . Markings shall be in accordance with MIL-STD-130.\r1.2 The material covered in this contract/purchase order will be used in a\rcrucial shipboard system enabling the launch and/or recovery of aircraft. The use of incorrect or defective material would create a high probability of failure resulting in a serious personnel injury, loss of life, loss of vital\rshipboard systems or loss of aircraft. Therefore,the material has been\rdesignated as Critical material and special control procedures are invoked\rto ensure receipt of correct material.\r1.3 Articles to be furnished hereunder shall be manufactured, tested and inspected in accordance with ;3975AS1400; drawing number ( ;30003; ) ;Most current revision.; , Revision ;Applies; and all details and specifications referenced therein.\r1.4 Unless expressly provided for elsewhere in this clause, equipment such as fixtures, jigs, dies, patterns, mylars, special tooling, test equipment, or any other manufacturing aid required for the manufacture and/or testing of the subject item(s) will not be\rprovided by the Government or any other source and is the sole responsibility of the contractor. The foregoing applies notwithstanding any reference to such equipment or the furnishing thereof that may be contained in any drawing or referenced specification.\r1.5 If MIL-STD-454 is referenced in the drawings or in the specification, the contractor is expected to show compliance with IPC/EIAJ-STD-001C.\r2. APPLICABLE DOCUMENTS\rDRAWING DATA=3975AS1020 |30003| B| |D| | | |\rDRAWING DATA=3975AS1022 |30003| | |D| | | |\rDRAWING DATA=3975AS1400 |30003| A| |D| | | |\rDRAWING DATA=3975AS1405 |30003| A| |D| | | |\rDRAWING DATA=3975AS1410 |30003| A| |D| | | |\rDRAWING DATA=3975AS1415 |30003| B| |D| | | |\rDRAWING DATA=3975AS1510 |30003| | |D| | | |\rDRAWING DATA=3975AS1530 |30003| A| |D| | | |\rDRAWING DATA=3975AS6260 |30003| A| |D| | | |\rDRAWING DATA=3975AS8055 |30003| A| |D| | | |\rDRAWING DATA=3975AS9999 |30003| A| |D| | | |\r3. REQUIREMENTS - NOT APPLICABLE\r4. QUALITY ASSURANCE\rQUALITY ASSURANCE REQUIREMENTS\rThe paragraphs shown below, when referenced on the QM1006 checklist, provide the detailed Quality Assurance requirements to be used for the particular procurement. These paragraphs shall only apply when the corresponding ?Yes? block has been checked on the\rassociated checklist.\r1.For purposes of this TDR, the term NDT shall refer to the following methods: MT - Magnetic Particle Testing, PT - Penetrant Inspection, UT - Ultrasonic Testing, RT - Radiographic Testing, and VT - Visual Testing.\r2.Companies performing NDT shall be NADCAP accredited, or a laboratory accredited by one of the organizations listed be-low as satisfying ISO 17025 (General requirements for the competence of testing and calibration laboratories). NDT certificates shall be\rbear the symbols of accreditation body.\ra.American Association for Laboratory Accreditation (A2LA)\rb.ANSI National Accreditation Board (ANAB)\rc.International Accreditation Service, Inc (IAS)\rd.National Voluntary Laboratory Accreditation Program (NVLAP)\re.Perry Johnson Laboratory Accreditation, Inc (PJLA)\rf.Canadian Association for Laboratory Accreditation Inc. (CALA)\rg.Standards Council of Canada (SCC)\r4.1 . Mandatory Inspection Requirements:\r100% Procurement Contracting Officer (PCO) mandatory inspection is required and shall be accomplished at source under the surveillance and final approval of the cognizant DCMAO Quality Assurance Representative (QAR).\rDuring production, mandatory inspection is required to be accomplished by the contractor as follows:\r A. Level of Inspection (LOI).\r 1. Critical characteristics: 100% inspection shall apply.\r 2. Major and Minor characteristics: LOI shall be in accordance with a sampling plan acceptable to the QAR.\r B. Critical characteristics:\r ;APPLIES;\r C. Major and Minor characteristics\r 1. Shall be defined by the contractor subject to QAR concurrence, unless defined on applicable drawings and associated specifications.\r4.2 SPECIAL INSPECTION REQUIREMENTS\r( ; ; ) MAGNETIC PARTICLE INSPECTION\r( ;APPLIES; ) SURFACE INSPECTION\r( ; ; ) PENETRANT INSPECTION\r( ; ; ) RADIOGRAPHIC INSPECTION\r( ; ; ) ULTRSONIC INSPECTION\r( ; ; ) HIGH SHOCK TEST\r( ; ; ) MECHANICAL VIBRATION TEST\r5. PACKAGING- MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE\r6. NOTES - NOT APPLICABLE\rTHIS ALRE ITEM HAS BEEN DEEM NON-CRITICAL ASPER TDR TDR 24-10064.\r"} Solicitation Number: SPRPA126QZA10 Type: Solicitation Base Type: Solicitation NAICS: 336413 Classification Code: 1680 Response Deadline: 2026-04-30T16:30:00-04:00 Office Address: PHILADELPHIA, PA POC: Telephone: 2673364024, JONATHAN.M.RIVERA@DLA.MIL
Get tenders like this in one daily alert
Use this notice as context when Tenqual drafts your search scope and fit criteria.