USCGC Gasconade SSDG Control Panel replacement

Country
United States
Published
December 23, 2025
Deadline
January 6, 2026

Description

{"description":" Statement of Work (SOW) \n Project Title: Replacement, Installation, and Calibration of CAT 10R-9661 - Kit ELEK GP Controller on both SSDG’s aboard CGC GASCONADE \n\n \n\t Background \n\tThe purpose of this project is to replace both existing controllers on the cutters SSDG’s with the CAT 10R-9661 - Kit ELEK GP, ensuring proper installation and calibration in accordance with the manufacturer's instructions. This work is critical to maintaining the operational efficiency and reliability of the equipment. \n \n\n \n\n \n\t Contractor Furnished Equipment \n \n\n \n\n Qty 2 – CAT Kit ELEK GP – 10R-6991 \n\n \n\n 3. Scope of Work \nThe contractor shall provide all necessary labor, tools, equipment, and expertise to perform the following tasks: \n\n \n\t Removal of Old Controller: \n\n\t \n\t\t Safely disconnect and remove the existing controllers from the equipment. \n\t\t Ensure no damage is caused to surrounding components during removal. \n\t \n\t \n\t Installation of New Controller: \n\t \n\t\t Install the CAT 10R-9661 - Kit ELEK GP controllers in accordance with the manufacturer's specifications. \n\t\t Verify that all connections are secure and properly aligned. \n\t \n\t \n\t Calibration of Controller: \n\t \n\t\t Calibrate the newly installed controllers per the manufacturer's instructions. \n\t\t Ensure the controllers are functioning optimally and meets operational requirements. \n\t \n\t \n \n\n 4. Deliverables \nThe contractor shall provide the following: \n\n \n\t Two fully installed and calibrated CAT 10R-9661 - Kit ELEK GP controllers. \n\t Documentation of calibration settings and procedures performed. \n\t A brief report confirming the successful completion of the work and equipment functionality. \n \n\n 5. Period of Performance \nThe work shall be completed within 5 business days from the start date agreed upon by the contractor and the project manager. \n\n 6. Location of Work \nThe work will be performed at CGC GASCONADE, 100 Arsenal Street, ST. Louis MO, 63118 \n\n 7. Contractor Responsibilities \nThe contractor shall: \n\n \n\t Comply with all safety regulations and standards during the execution of work. \n\t Provide qualified personnel to perform the tasks outlined in this SOW. \n\t Ensure all tools and equipment used are in good working condition. \n \n\n 8. Government Furnished Equipment (GFE) \nNone \n\n 9. Acceptance Criteria \nThe work will be considered complete when: \n\n \n\t The old controllers have been removed without damage to the equipment. \n\t The new controllers have been installed and calibrated per the manufacturer's instructions. \n\t The equipment is fully operational and meets performance standards. \n \n\n 10. Points of Contact \nQuestions related to anything listed within this statement of work, or access to the ship should be directed to: MKCS Matt Morin, 571-607-9267, matthew.j.morin@uscg.mil \n"} Solicitation Number: 70Z08526Q0002157 Type: Combined Synopsis/Solicitation Base Type: Combined Synopsis/Solicitation NAICS: 336611 Classification Code: J020 Response Deadline: 2026-01-06T08:00:00-08:00 Office Address: ALAMEDA, CA Place of Performance: Saint Louis, Missouri, 63118 POC: DONNA O'NEAL, Donna.J.O'Neal@uscg.mil, 5103931145 POC: Lindsay Mongiovi, lindsay.n.mongiovi@uscg.mil, 5716086752 {"description":" Statement of Work (SOW) \n Project Title: Replacement, Installation, and Calibration of CAT 10R-9661 - Kit ELEK GP Controller on both SSDG’s aboard CGC GASCONADE \n\n \n\t Background \n\tThe purpose of this project is to replace both existing controllers on the cutters SSDG’s with the CAT 10R-9661 - Kit ELEK GP, ensuring proper installation and calibration in accordance with the manufacturer's instructions. This work is critical to maintaining the operational efficiency and reliability of the equipment. \n \n\n \n\n \n\t Contractor Furnished Equipment \n \n\n \n\n Qty 2 – CAT Kit ELEK GP – 10R-6991 \n\n \n\n 3. Scope of Work \nThe contractor shall provide all necessary labor, tools, equipment, and expertise to perform the following tasks: \n\n \n\t Removal of Old Controller: \n\n\t \n\t\t Safely disconnect and remove the existing controllers from the equipment. \n\t\t Ensure no damage is caused to surrounding components during removal. \n\t \n\t \n\t Installation of New Controller: \n\t \n\t\t Install the CAT 10R-9661 - Kit ELEK GP controllers in accordance with the manufacturer's specifications. \n\t\t Verify that all connections are secure and properly aligned. \n\t \n\t \n\t Calibration of Controller: \n\t \n\t\t Calibrate the newly installed controllers per the manufacturer's instructions. \n\t\t Ensure the controllers are functioning optimally and meets operational requirements. \n\t \n\t \n \n\n 4. Deliverables \nThe contractor shall provide the following: \n\n \n\t Two fully installed and calibrated CAT 10R-9661 - Kit ELEK GP controllers. \n\t Documentation of calibration settings and procedures performed. \n\t A brief report confirming the successful completion of the work and equipment functionality. \n \n\n 5. Period of Performance \nThe work shall be completed within 5 business days from the start date agreed upon by the contractor and the project manager. \n\n 6. Location of Work \nThe work will be performed at CGC GASCONADE, 100 Arsenal Street, ST. Louis MO, 63118 \n\n 7. Contractor Responsibilities \nThe contractor shall: \n\n \n\t Comply with all safety regulations and standards during the execution of work. \n\t Provide qualified personnel to perform the tasks outlined in this SOW. \n\t Ensure all tools and equipment used are in good working condition. \n \n\n 8. Government Furnished Equipment (GFE) \nNone \n\n 9. Acceptance Criteria \nThe work will be considered complete when: \n\n \n\t The old controllers have been removed without damage to the equipment. \n\t The new controllers have been installed and calibrated per the manufacturer's instructions. \n\t The equipment is fully operational and meets performance standards. \n \n\n 10. Points of Contact \nQuestions related to anything listed within this statement of work, or access to the ship should be directed to: MKCS Matt Morin, 571-607-9267, matthew.j.morin@uscg.mil \n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
USCGC Gasconade SSDG Control Panel replacement tender | Tenqual