Back to search
SAM.govNotice eadb62b5dfad433e9dd972e1d5fbc63f

J066--Intent to sole sourc Cytek Aurora Laser Service Contract

Country
United States
Published
December 2, 2025
Deadline
December 8, 2025

Description

{"description":"The Department of Veterans Affairs intends to issue sole-source firm-fixed priced award contract, to Cytek Biosciences, 47215 Lakeview Blvd, Fremont, CA 95438.\nA sole source procurement will be issued to Cytek Biosciences as they are the only vendor capable of fully performing the service. Due to the specialized equipment, all work for the duration of the contract shall be performed by authroized Cytek Biosciences field service engineer. This contract requires the Contractor to provide annual maintenance and any necessary repairs of the Cytek Biosciences Cytek Aurora Flow Cytometer located at TVHS VA Medical Center, located in Nashville, TN. The Cytek Aurora Flow Cytometer is used for VA related research.\nThe contract is expected to be awarded in accordance with FAR 13.106-1(b)- Soliciting from a single source. The anticipated award date is 12/18/2025. \nNAICS code: 811210, Electronic and Precision Equipment Repair and Maintenance\nSBA Size Standard: $34 Million Dollars \n\nPSC: J066 maint/repair/rebuild of equipment- instruments and laboratory equipment\n\nSTATEMENT OF WORK:\nThe Contractor shall provide a Premium Service Plan for the Cytek Aurora Flow Cytometer, to\nensure proper working conditions, consisting of:\nTwo (2) preventive maintenance inspections per year;\nAll non-consumable parts, travel and labor for repair visits;\n24-hour (maximum) response time for technical support and 48-hour (maximum) response\ntime for non-functional instruments, with escalation to the top of priority field service job queue;\nOn-site and remote assistance, including assistance with panel design, data analsys, assay optimization and troubleshoooting, and general scientific consultation by a dedicated region Technical Applications Specialist; and\nUnlimited telephone technical support.\n\nThe contractor shall a provide an authroized Cytek Biosciences engineer to physically present to the Research Lab, located in Nashville, TN, at least twice during a one-year period to perform\nannual preventative maintanence on the Cytek Aurora Flow Cytometer.\n\nThe contractor shall a provide an authroized Cytek Biosciences engineer to perform diagnostic and repair work if the Cytek Aurora Flow Cytometer has an issue.\nThe annual preventive maintenance will be booked with the Contractor. Any diagnostics or\nrepairs will be scheduled as necessary for the duration of the plan. The authroized Cytek\n\nSpecial Notice\n\nSpecial Notice\n\nPage 4 of 4\nSpecial Notice\n*= Required Field\nSpecial Notice\n\nPage 1 of 4\nBiosciences engineer will be in the Research Lab during normal work hours of 8am 4:30pm\nMonday through Friday, when necessary.\nGOVERNMENT HOLIDAYS:\nNew Year s Day January 1\nMartin Luther King s Birthday . 3rd Monday in January\nPresident s Day . 3rd Monday in February\nMemorial Day Last Monday in May\nJuneteenth ...Jun 19th\nIndependence Day ..July 4th\nLabor Day 1st Monday in September\nColumbus Day 2nd Monday in October\nVeteran s Day November 11\nThanksgiving Day . Last Thursday in November\nChristmas Day ........December 25\nAny other day designated by the President as a national holiday. When one of the holidays falls on a Sunday, the following Monday will be observed as a legal holiday. When holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by US Government agencies.\n\nThe contractor shall be fully responsible for compliance with all VA, local, state, and Federal occupational safety laws, rules, and regulations.\n\nThe contractor shall follow life and safety codes and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients.\n\nThe contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working procedures.\n\nAll work for the duration of the contract shall be performed by certified trained technicians.\nAll Contractor employees shall be identified by a distinctive name plate, emblem, or patch attached in a prominent place to an outer garment.\n\nThe Contractor shall ensure that Contractor s employees entering the VA facility observe and\ncomply with all VA policies, regulations, and procedures concerning fire, safety, environmental protection, sanitation, security, traffic, parking, \"off limits\" areas.\n\nThe Contractor shall remove from the job site any employee for reasons of misconduct or security. The removal of such a person shall not relieve the Contractor of the requirement to provide personnel to perform adequate and timely service.\n\n\nTHIS NOTICE OF INTENT IS NOT A SOLICITATION OR REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement within seven calendar days after publication of this notice. \nA determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. Information received will normally be considered solely for determining whether to conduct a competitive procurement. The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award and must submit a current authorized distributor letter from the manufacturer. \nInterested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE 36C24926Q0055 in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Carmen Hanczyk, Contract Specialist, by email at Carmen.Hanczyk@va.gov NO LATER THAN Dec 8th, 2025 @ 11:00AM EST. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements.\n\n\n"} Solicitation Number: 36C24926Q0055 Type: Special Notice Base Type: Special Notice NAICS: 811210 Classification Code: J066 Response Deadline: 2025-12-08T11:00:00-05:00 Office Address: MURFREESBORO, TN POC: Carmen Hanczyk, Carmen.Hanczyk@va.gov, 615-225-5973 {"description":"The Department of Veterans Affairs intends to issue sole-source firm-fixed priced award contract, to Cytek Biosciences, 47215 Lakeview Blvd, Fremont, CA 95438.\nA sole source procurement will be issued to Cytek Biosciences as they are the only vendor capable of fully performing the service. Due to the specialized equipment, all work for the duration of the contract shall be performed by authroized Cytek Biosciences field service engineer. This contract requires the Contractor to provide annual maintenance and any necessary repairs of the Cytek Biosciences Cytek Aurora Flow Cytometer located at TVHS VA Medical Center, located in Nashville, TN. The Cytek Aurora Flow Cytometer is used for VA related research.\nThe contract is expected to be awarded in accordance with FAR 13.106-1(b)- Soliciting from a single source. The anticipated award date is 12/18/2025. \nNAICS code: 811210, Electronic and Precision Equipment Repair and Maintenance\nSBA Size Standard: $34 Million Dollars \n\nPSC: J066 maint/repair/rebuild of equipment- instruments and laboratory equipment\n\nSTATEMENT OF WORK:\nThe Contractor shall provide a Premium Service Plan for the Cytek Aurora Flow Cytometer, to\nensure proper working conditions, consisting of:\nTwo (2) preventive maintenance inspections per year;\nAll non-consumable parts, travel and labor for repair visits;\n24-hour (maximum) response time for technical support and 48-hour (maximum) response\ntime for non-functional instruments, with escalation to the top of priority field service job queue;\nOn-site and remote assistance, including assistance with panel design, data analsys, assay optimization and troubleshoooting, and general scientific consultation by a dedicated region Technical Applications Specialist; and\nUnlimited telephone technical support.\n\nThe contractor shall a provide an authroized Cytek Biosciences engineer to physically present to the Research Lab, located in Nashville, TN, at least twice during a one-year period to perform\nannual preventative maintanence on the Cytek Aurora Flow Cytometer.\n\nThe contractor shall a provide an authroized Cytek Biosciences engineer to perform diagnostic and repair work if the Cytek Aurora Flow Cytometer has an issue.\nThe annual preventive maintenance will be booked with the Contractor. Any diagnostics or\nrepairs will be scheduled as necessary for the duration of the plan. The authroized Cytek\n\nSpecial Notice\n\nSpecial Notice\n\nPage 4 of 4\nSpecial Notice\n*= Required Field\nSpecial Notice\n\nPage 1 of 4\nBiosciences engineer will be in the Research Lab during normal work hours of 8am 4:30pm\nMonday through Friday, when necessary.\nGOVERNMENT HOLIDAYS:\nNew Year s Day January 1\nMartin Luther King s Birthday . 3rd Monday in January\nPresident s Day . 3rd Monday in February\nMemorial Day Last Monday in May\nJuneteenth ...Jun 19th\nIndependence Day ..July 4th\nLabor Day 1st Monday in September\nColumbus Day 2nd Monday in October\nVeteran s Day November 11\nThanksgiving Day . Last Thursday in November\nChristmas Day ........December 25\nAny other day designated by the President as a national holiday. When one of the holidays falls on a Sunday, the following Monday will be observed as a legal holiday. When holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by US Government agencies.\n\nThe contractor shall be fully responsible for compliance with all VA, local, state, and Federal occupational safety laws, rules, and regulations.\n\nThe contractor shall follow life and safety codes and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients.\n\nThe contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working procedures.\n\nAll work for the duration of the contract shall be performed by certified trained technicians.\nAll Contractor employees shall be identified by a distinctive name plate, emblem, or patch attached in a prominent place to an outer garment.\n\nThe Contractor shall ensure that Contractor s employees entering the VA facility observe and\ncomply with all VA policies, regulations, and procedures concerning fire, safety, environmental protection, sanitation, security, traffic, parking, \"off limits\" areas.\n\nThe Contractor shall remove from the job site any employee for reasons of misconduct or security. The removal of such a person shall not relieve the Contractor of the requirement to provide personnel to perform adequate and timely service.\n\n\nTHIS NOTICE OF INTENT IS NOT A SOLICITATION OR REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement within seven calendar days after publication of this notice. \nA determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. Information received will normally be considered solely for determining whether to conduct a competitive procurement. The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award and must submit a current authorized distributor letter from the manufacturer. \nInterested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE 36C24926Q0055 in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Carmen Hanczyk, Contract Specialist, by email at Carmen.Hanczyk@va.gov NO LATER THAN Dec 8th, 2025 @ 11:00AM EST. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements.\n\n\n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
J066--Intent to sole sourc Cytek Aurora Laser Service Contract tender | Tenqual