Back to search
SAM.govNotice fd1a8a49c6254d9aa0532c9b2a73d532

LAPTOP,ALTERED

Country
United States
Published
October 31, 2025
Deadline
October 31, 2025

Description

{"description":"CONTACT INFORMATION|4|N744.13|BL5|n/a|gordon.kohl@navy.mil|\rITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19||||||||||||||||||||\rINSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2|||\rNAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|WSS|\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11||||||||||||\rOPTION FOR INCREASED QUANTITY (MAR 1989)|1|365 days|\rALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2024)|13||||||||||||||\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5||||||\rBUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1||\rANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025) (DEVIATION 2025-O0003)|13|334111|1250||||||||||||\rNOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||x|\rQuantity changed.\rThis solicitation is for NAVSUP to consider to repair existing unit(s). No purchases of new, used, or refurbished units will be considered and are not considered offers, since this is for repair only of an existing unit(s). In order for the government to consider\ran offer, if vendor is not already pre-approved, thevendor must provide, along with and as part of their offer, a statement that the vendor has access to the data or the rights to use the data needed to repair this part. This data is not usually owned by the\rGovernment and will not be provided. For solicitations that are already determined to be sole source to another vendor, or limited, your information will be considered as a potential source for future awards, not this award, should you pursue to be vetted and\rapproved as a source. Authorized distributors confirmed by the OEM may be consideredas a potential source. Provide the letter from the OEM stating that you are \"authorized.\"\rAll quotes need to include these cost factors, at a minimum: IUID, CAV asset processing, and packaging.\rProvide an estimated MLO price, monetary limitation order, which is an approximation of a standard evaluation AND repair. It is not a price for a worst case scenario. It is not a NTE, which is not accepted. It does NOT have a ceiling price. Funding can be added\r after doing the eval, upon proposing the firm repair price, subject to negotiations. Eval only pricing is not acceptable.\r1. Unit MLO price, and unit option MLO price, if any, to evaluate AND repair _________.\r2. Tear down and evaluate ONLY price, in case unit is not repaired, beyond repair, or \"no fault found\" ________ NTE, not to exceed, price, to return to a depot.\r3. New item price, for the same quantity being solicited, in an each price________ (ROM estimate is fine)\r4. Quote expiration date ______. (quotes valid until at least 30 Sep, if feasible.)\r5. Repair turn-around-time for complete repair of first unit, not just for the eval portion:___________\r6. If more than one unit to repair, after shipping the first unit, the number of assets able to ship each month thereafter ________\r7. Repair Location (CAGE):___________\r8. Source Inspection Location (CAGE): ________ Note, inspection by DCMA is required prior to shipping. Destination Inspection is not allowed.\r9. Source Acceptance Location (CAGE): ________ Inspection by DCMA is required prior to shipping. Destination Acceptance is not allowed.\r10. Pack Location (CAGE): ________ Indicate if packaging will be done by an outside source.\rRequired shipping procedure is military packaging, IUID, and CAV, so include these in your costs.\r11. Is this repair going to be an overhaul? _____\r12. Was this manufactured in the US? ______\r13. Do you need the quantity incremented down to the 1 each level per SLIN to better track SLIN to the unit job number? ______\r14. POC name and email: ____________________________\rWhen the evaluation is done, an adequate proposal must include in it:\rYour Evaluation Findings from your internal job packet, for each unit, that includes:\r- the condition of the unit as received;\r- parts missing. (If parts are missing of a very significant value, notify as soon as discovered) ;\r- parts that need replaced;\r- parts that need refurbished, (optional);\r- out of specs and any tests the unit failed\rScope of work to do the repair\rThe resultant award will be issued bilaterally, if not on a BOA, requiring written acceptance prior to execution.\r1. SCOPE\r1.1 This contract/purchase order contains the requirements for repair and the contract quality requirements for the LAPTOP,ALTERED .\r2. APPLICABLE DOCUMENTS\r2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.\r2.1.1 \"Document References\" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order.\r3. REQUIREMENTS\r3.1 Cage Code/Reference Number Items - The LAPTOP,ALTERED repaired under this contract/purchase order shall meet the operational and functional requirements as represented by the Cage Code(s) and reference number(s) listed below. All repair work shall be\rperformed in accordance with the contractors repair/overhaul standard practices, manuals and directives including but not limited to drawings, technical orders, manufacturing operations, tooling instructions, approved repair standards and any other contractor\ror government approved documents developed to provide technical repair procedures.\rCAGE___Ref. No.\r;34EA9 1012327-1;\r3.2 Marking - This item shall be physically identified in accordance\rwith ;MIL-STD-130, REV N, 16 NOV 2012; .\r3.3 Changes in Design, Material Servicing, or Part Number - Except for a Code 1 change, which shall be processed as provided in the code statement shown below, no substitution of items shall be made until the NAVICP-MECH Contracting Officer has notified and\rapproval has been given by issuance of a written change order. When any change in design, material, servicing or part number is made to replace or substitute any item to be furnished on this contract/purchase order, the Contractor shall furnish, for the\rsubstituting/replacement item, a drawing and an explanation of the reason for the change, explaining the reason therefor. If finished detail drawings are not available, shop drawings in the form used by the manufacturer will be acceptable for Government\revaluation. When notifying the Procurement Contracting Officer of the reasons for making substitutions, the type of change shall be indicated by code number in accordance with one of the following statements:\rCode 1: PART NUMBER CHANGE ONLY - If the Manufacturer's Part Number indicated thereon has changed, but the parts are identical in all respects, supply the item and advise NAVICP-MECH immediately of the new part number.\rCode 2: Assembly (or set or kit) not furnished - Used following detail parts.\rCode 3: Part not furnished separately - Use assembly.\rCode 4: Part redesigned - Old and new parts are completely interchangeable.\rCode 5: Part redesigned - New part replaces old. Old part cannot replace new.\rCode 6: Part redesigned - Parts not interchangeable.\r4. QUALITY ASSURANCE\r4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order,\rthe Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the\rspecification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.\r4.2 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any\rinspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance\rdoes not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material.\r4.3 Records - Records of all inspection work by the Contractor shall be kept complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies.\r4.4 Inspection/Testing Repaired Items - The Contractor shall perform all inspection and testing requirements as specified in the original manufacturer's specifications and drawings.\r5. PACKAGING\r5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below.\rMIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE\r6. NOTES\r6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS)\r(i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/\rA. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk.\rB. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies.\rC. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to:\rCommander, Indian Head Division, Naval Surface Warfare Center\rCode 8410P, 101 Strauss Avenue\rIndian Head, MD 20640-5035\rD. On post-award actions, requests for \"Official Use Only\" and \"NOFORN\" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for\rcertification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document.\rE. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from:\rContracting Officer\rNAVSUP-WSS\rCode 87321\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rF. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue:\rCommanding Officer\rNAVSUP-WSS\rCode 009\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rG. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from:\rCommanding Officer\rNAVSUP-WSS\rCode 1 Support Branch\r700 Robbins Avenue\rPhiladelphia, Pa. 19111-5094\rH. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS.\r6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a \"Distribution Statement\" to inform the contractor of the limits of distribution, and the safeguarding of the information\rcontained on those documents and drawings.\r There are 7 (seven) seperate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows:\rA... approved for public release; distribution is unlimited.\rB... distribution authorized to US Governments agencies only.\rC... distribution authorized to US Government agencies and their contractors.\rD... distribution authorized to DoD and DoD contractors only.\rE... distribution authorized to DoD Components only.\rF... further distribution only as directed by Commander, Naval Sea\r Systems Command, code 09T.\rX... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical\r data in accordance with OPNAVINST 5510.161.\r6.3 Notice To Distributors/Offerors - Consideration for award of contract shall be given only to authorized distributors of the original manufacturer's item represented in this solicitation. If you desire to be considered as a potential source for award of\rthis contract, proof of being an authorized distributor shall be provided on company letterhead signed by a responsible company official and sent with your offer to the Procurement Contracting Officer.\r1. SCOPE\r1.1 This contract/purchase order contains the requirements for repair and the contract quality requirements for the VME BUS BASED SBC,W .\r2. APPLICABLE DOCUMENTS\r2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.\r2.1.1 \"Document References\" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order.\r3. REQUIREMENTS\r3.1 Cage Code/Reference Number Items - The VME BUS BASED SBC,W repaired under this contract/purchase order shall meet the operational and functional requirements as represented by the Cage Code(s) and reference number(s) listed below. All repair work shall\rbe performed in accordance with the contractors repair/overhaul standard practices, manuals and directives including but not limited to drawings, technical orders, manufacturing operations, tooling instructions, approved repair standards and any other\rcontractor or government approved documents developed to provide technical repair procedures.\rCAGE___Ref. No.\r;34EA9 1012297-3;\r3.2 Electrostatic Discharge Control - The Contractor shall comply with the electrostatic discharge control requirements established in ANSI/ESD S20.20, \"ESD Association Standard for the Development of an Electrostatic Discharge Control Program for Protection\rof Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices)\", which superseded MIL-STD-1686C.\r3.3 Marking - This item shall be physically identified in accordance\rwith ;MIL-STD-130, REV N, 16 NOV 2012; .\r3.4 Changes in Design, Material Servicing, or Part Number - Except for a Code 1 change, which shall be processed as provided in the code statement shown below, no substitution of items shall be made until the NAVICP-MECH Contracting Officer has notified and\rapproval has been given by issuance of a written change order. When any change in design, material, servicing or part number is made to replace or substitute any item to be furnished on this contract/purchase order, the Contractor shall furnish, for the\rsubstituting/replacement item, a drawing and an explanation of the reason for the change, explaining the reason therefor. If finished detail drawings are not available, shop drawings in the form used by the manufacturer will be acceptable for Government\revaluation. When notifying the Procurement Contracting Officer of the reasons for making substitutions, the type of change shall be indicated by code number in accordance with one of the following statements:\rCode 1: PART NUMBER CHANGE ONLY - If the Manufacturer's Part Number indicated thereon has changed, but the parts are identical in all respects, supply the item and advise NAVICP-MECH immediately of the new part number.\rCode 2: Assembly (or set or kit) not furnished - Used following detail parts.\rCode 3: Part not furnished separately - Use assembly.\rCode 4: Part redesigned - Old and new parts are completely interchangeable.\rCode 5: Part redesigned - New part replaces old. Old part cannot replace new.\rCode 6: Part redesigned - Parts not interchangeable.\r4. QUALITY ASSURANCE\r4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order,\rthe Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the\rspecification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.\r4.2 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any\rinspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance\rdoes not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material.\r4.3 Records - Records of all inspection work by the Contractor shall be kept complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies.\r4.4 Inspection/Testing Repaired Items - The Contractor shall perform all inspection and testing requirements as specified in the original manufacturer's specifications and drawings.\r5. PACKAGING\r5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below.\rMIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE\r6. NOTES\r6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS)\r(i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/\rA. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk.\rB. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies.\rC. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to:\rCommander, Indian Head Division, Naval Surface Warfare Center\rCode 8410P, 101 Strauss Avenue\rIndian Head, MD 20640-5035\rD. On post-award actions, requests for \"Official Use Only\" and \"NOFORN\" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for\rcertification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document.\rE. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from:\rContracting Officer\rNAVSUP-WSS\rCode 87321\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rF. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue:\rCommanding Officer\rNAVSUP-WSS\rCode 009\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rG. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from:\rCommanding Officer\rNAVSUP-WSS\rCode 1 Support Branch\r700 Robbins Avenue\rPhiladelphia, Pa. 19111-5094\rH. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS.\r6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a \"Distribution Statement\" to inform the contractor of the limits of distribution, and the safeguarding of the information\rcontained on those documents and drawings.\r There are 7 (seven) seperate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows:\rA... approved for public release; distribution is unlimited.\rB... distribution authorized to US Governments agencies only.\rC... distribution authorized to US Government agencies and their contractors.\rD... distribution authorized to DoD and DoD contractors only.\rE... distribution authorized to DoD Components only.\rF... further distribution only as directed by Commander, Naval Sea\r Systems Command, code 09T.\rX... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical\r data in accordance with OPNAVINST 5510.161.\r6.3 Notice To Distributors/Offerors - Consideration for award of contract shall be given only to authorized distributors of the original manufacturer's item represented in this solicitation. If you desire to be considered as a potential source for award of\rthis contract, proof of being an authorized distributor shall be provided on company letterhead signed by a responsible company official and sent with your offer to the Procurement Contracting Officer.\r"} Solicitation Number: N0010425QNC32 Type: Solicitation Base Type: Solicitation NAICS: 334111 Classification Code: 7B22 Response Deadline: 2025-10-31T16:30:00-04:00 Office Address: MECHANICSBURG, PA POC: Telephone: 7176053629, GORDON.KOHL.CIV@US.NAVY.MIL {"description":"CONTACT INFORMATION|4|N744.13|BL5|n/a|gordon.kohl@navy.mil|\rITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19||||||||||||||||||||\rINSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2|||\rNAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|WSS|\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11||||||||||||\rOPTION FOR INCREASED QUANTITY (MAR 1989)|1|365 days|\rALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2024)|13||||||||||||||\rBUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5||||||\rBUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1||\rANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025) (DEVIATION 2025-O0003)|13|334111|1250||||||||||||\rNOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||x|\rQuantity changed.\rThis solicitation is for NAVSUP to consider to repair existing unit(s). No purchases of new, used, or refurbished units will be considered and are not considered offers, since this is for repair only of an existing unit(s). In order for the government to consider\ran offer, if vendor is not already pre-approved, thevendor must provide, along with and as part of their offer, a statement that the vendor has access to the data or the rights to use the data needed to repair this part. This data is not usually owned by the\rGovernment and will not be provided. For solicitations that are already determined to be sole source to another vendor, or limited, your information will be considered as a potential source for future awards, not this award, should you pursue to be vetted and\rapproved as a source. Authorized distributors confirmed by the OEM may be consideredas a potential source. Provide the letter from the OEM stating that you are \"authorized.\"\rAll quotes need to include these cost factors, at a minimum: IUID, CAV asset processing, and packaging.\rProvide an estimated MLO price, monetary limitation order, which is an approximation of a standard evaluation AND repair. It is not a price for a worst case scenario. It is not a NTE, which is not accepted. It does NOT have a ceiling price. Funding can be added\r after doing the eval, upon proposing the firm repair price, subject to negotiations. Eval only pricing is not acceptable.\r1. Unit MLO price, and unit option MLO price, if any, to evaluate AND repair _________.\r2. Tear down and evaluate ONLY price, in case unit is not repaired, beyond repair, or \"no fault found\" ________ NTE, not to exceed, price, to return to a depot.\r3. New item price, for the same quantity being solicited, in an each price________ (ROM estimate is fine)\r4. Quote expiration date ______. (quotes valid until at least 30 Sep, if feasible.)\r5. Repair turn-around-time for complete repair of first unit, not just for the eval portion:___________\r6. If more than one unit to repair, after shipping the first unit, the number of assets able to ship each month thereafter ________\r7. Repair Location (CAGE):___________\r8. Source Inspection Location (CAGE): ________ Note, inspection by DCMA is required prior to shipping. Destination Inspection is not allowed.\r9. Source Acceptance Location (CAGE): ________ Inspection by DCMA is required prior to shipping. Destination Acceptance is not allowed.\r10. Pack Location (CAGE): ________ Indicate if packaging will be done by an outside source.\rRequired shipping procedure is military packaging, IUID, and CAV, so include these in your costs.\r11. Is this repair going to be an overhaul? _____\r12. Was this manufactured in the US? ______\r13. Do you need the quantity incremented down to the 1 each level per SLIN to better track SLIN to the unit job number? ______\r14. POC name and email: ____________________________\rWhen the evaluation is done, an adequate proposal must include in it:\rYour Evaluation Findings from your internal job packet, for each unit, that includes:\r- the condition of the unit as received;\r- parts missing. (If parts are missing of a very significant value, notify as soon as discovered) ;\r- parts that need replaced;\r- parts that need refurbished, (optional);\r- out of specs and any tests the unit failed\rScope of work to do the repair\rThe resultant award will be issued bilaterally, if not on a BOA, requiring written acceptance prior to execution.\r1. SCOPE\r1.1 This contract/purchase order contains the requirements for repair and the contract quality requirements for the LAPTOP,ALTERED .\r2. APPLICABLE DOCUMENTS\r2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.\r2.1.1 \"Document References\" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order.\r3. REQUIREMENTS\r3.1 Cage Code/Reference Number Items - The LAPTOP,ALTERED repaired under this contract/purchase order shall meet the operational and functional requirements as represented by the Cage Code(s) and reference number(s) listed below. All repair work shall be\rperformed in accordance with the contractors repair/overhaul standard practices, manuals and directives including but not limited to drawings, technical orders, manufacturing operations, tooling instructions, approved repair standards and any other contractor\ror government approved documents developed to provide technical repair procedures.\rCAGE___Ref. No.\r;34EA9 1012327-1;\r3.2 Marking - This item shall be physically identified in accordance\rwith ;MIL-STD-130, REV N, 16 NOV 2012; .\r3.3 Changes in Design, Material Servicing, or Part Number - Except for a Code 1 change, which shall be processed as provided in the code statement shown below, no substitution of items shall be made until the NAVICP-MECH Contracting Officer has notified and\rapproval has been given by issuance of a written change order. When any change in design, material, servicing or part number is made to replace or substitute any item to be furnished on this contract/purchase order, the Contractor shall furnish, for the\rsubstituting/replacement item, a drawing and an explanation of the reason for the change, explaining the reason therefor. If finished detail drawings are not available, shop drawings in the form used by the manufacturer will be acceptable for Government\revaluation. When notifying the Procurement Contracting Officer of the reasons for making substitutions, the type of change shall be indicated by code number in accordance with one of the following statements:\rCode 1: PART NUMBER CHANGE ONLY - If the Manufacturer's Part Number indicated thereon has changed, but the parts are identical in all respects, supply the item and advise NAVICP-MECH immediately of the new part number.\rCode 2: Assembly (or set or kit) not furnished - Used following detail parts.\rCode 3: Part not furnished separately - Use assembly.\rCode 4: Part redesigned - Old and new parts are completely interchangeable.\rCode 5: Part redesigned - New part replaces old. Old part cannot replace new.\rCode 6: Part redesigned - Parts not interchangeable.\r4. QUALITY ASSURANCE\r4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order,\rthe Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the\rspecification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.\r4.2 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any\rinspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance\rdoes not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material.\r4.3 Records - Records of all inspection work by the Contractor shall be kept complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies.\r4.4 Inspection/Testing Repaired Items - The Contractor shall perform all inspection and testing requirements as specified in the original manufacturer's specifications and drawings.\r5. PACKAGING\r5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below.\rMIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE\r6. NOTES\r6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS)\r(i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/\rA. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk.\rB. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies.\rC. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to:\rCommander, Indian Head Division, Naval Surface Warfare Center\rCode 8410P, 101 Strauss Avenue\rIndian Head, MD 20640-5035\rD. On post-award actions, requests for \"Official Use Only\" and \"NOFORN\" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for\rcertification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document.\rE. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from:\rContracting Officer\rNAVSUP-WSS\rCode 87321\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rF. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue:\rCommanding Officer\rNAVSUP-WSS\rCode 009\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rG. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from:\rCommanding Officer\rNAVSUP-WSS\rCode 1 Support Branch\r700 Robbins Avenue\rPhiladelphia, Pa. 19111-5094\rH. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS.\r6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a \"Distribution Statement\" to inform the contractor of the limits of distribution, and the safeguarding of the information\rcontained on those documents and drawings.\r There are 7 (seven) seperate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows:\rA... approved for public release; distribution is unlimited.\rB... distribution authorized to US Governments agencies only.\rC... distribution authorized to US Government agencies and their contractors.\rD... distribution authorized to DoD and DoD contractors only.\rE... distribution authorized to DoD Components only.\rF... further distribution only as directed by Commander, Naval Sea\r Systems Command, code 09T.\rX... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical\r data in accordance with OPNAVINST 5510.161.\r6.3 Notice To Distributors/Offerors - Consideration for award of contract shall be given only to authorized distributors of the original manufacturer's item represented in this solicitation. If you desire to be considered as a potential source for award of\rthis contract, proof of being an authorized distributor shall be provided on company letterhead signed by a responsible company official and sent with your offer to the Procurement Contracting Officer.\r1. SCOPE\r1.1 This contract/purchase order contains the requirements for repair and the contract quality requirements for the VME BUS BASED SBC,W .\r2. APPLICABLE DOCUMENTS\r2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.\r2.1.1 \"Document References\" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order.\r3. REQUIREMENTS\r3.1 Cage Code/Reference Number Items - The VME BUS BASED SBC,W repaired under this contract/purchase order shall meet the operational and functional requirements as represented by the Cage Code(s) and reference number(s) listed below. All repair work shall\rbe performed in accordance with the contractors repair/overhaul standard practices, manuals and directives including but not limited to drawings, technical orders, manufacturing operations, tooling instructions, approved repair standards and any other\rcontractor or government approved documents developed to provide technical repair procedures.\rCAGE___Ref. No.\r;34EA9 1012297-3;\r3.2 Electrostatic Discharge Control - The Contractor shall comply with the electrostatic discharge control requirements established in ANSI/ESD S20.20, \"ESD Association Standard for the Development of an Electrostatic Discharge Control Program for Protection\rof Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices)\", which superseded MIL-STD-1686C.\r3.3 Marking - This item shall be physically identified in accordance\rwith ;MIL-STD-130, REV N, 16 NOV 2012; .\r3.4 Changes in Design, Material Servicing, or Part Number - Except for a Code 1 change, which shall be processed as provided in the code statement shown below, no substitution of items shall be made until the NAVICP-MECH Contracting Officer has notified and\rapproval has been given by issuance of a written change order. When any change in design, material, servicing or part number is made to replace or substitute any item to be furnished on this contract/purchase order, the Contractor shall furnish, for the\rsubstituting/replacement item, a drawing and an explanation of the reason for the change, explaining the reason therefor. If finished detail drawings are not available, shop drawings in the form used by the manufacturer will be acceptable for Government\revaluation. When notifying the Procurement Contracting Officer of the reasons for making substitutions, the type of change shall be indicated by code number in accordance with one of the following statements:\rCode 1: PART NUMBER CHANGE ONLY - If the Manufacturer's Part Number indicated thereon has changed, but the parts are identical in all respects, supply the item and advise NAVICP-MECH immediately of the new part number.\rCode 2: Assembly (or set or kit) not furnished - Used following detail parts.\rCode 3: Part not furnished separately - Use assembly.\rCode 4: Part redesigned - Old and new parts are completely interchangeable.\rCode 5: Part redesigned - New part replaces old. Old part cannot replace new.\rCode 6: Part redesigned - Parts not interchangeable.\r4. QUALITY ASSURANCE\r4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order,\rthe Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the\rspecification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.\r4.2 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any\rinspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance\rdoes not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material.\r4.3 Records - Records of all inspection work by the Contractor shall be kept complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies.\r4.4 Inspection/Testing Repaired Items - The Contractor shall perform all inspection and testing requirements as specified in the original manufacturer's specifications and drawings.\r5. PACKAGING\r5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below.\rMIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE\r6. NOTES\r6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS)\r(i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/\rA. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk.\rB. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies.\rC. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to:\rCommander, Indian Head Division, Naval Surface Warfare Center\rCode 8410P, 101 Strauss Avenue\rIndian Head, MD 20640-5035\rD. On post-award actions, requests for \"Official Use Only\" and \"NOFORN\" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for\rcertification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document.\rE. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from:\rContracting Officer\rNAVSUP-WSS\rCode 87321\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rF. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue:\rCommanding Officer\rNAVSUP-WSS\rCode 009\r5450 Carlisle Pike\rP.O. Box 2020\rMechanicsburg, Pa. 17055-0788\rG. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from:\rCommanding Officer\rNAVSUP-WSS\rCode 1 Support Branch\r700 Robbins Avenue\rPhiladelphia, Pa. 19111-5094\rH. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS.\r6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a \"Distribution Statement\" to inform the contractor of the limits of distribution, and the safeguarding of the information\rcontained on those documents and drawings.\r There are 7 (seven) seperate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows:\rA... approved for public release; distribution is unlimited.\rB... distribution authorized to US Governments agencies only.\rC... distribution authorized to US Government agencies and their contractors.\rD... distribution authorized to DoD and DoD contractors only.\rE... distribution authorized to DoD Components only.\rF... further distribution only as directed by Commander, Naval Sea\r Systems Command, code 09T.\rX... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical\r data in accordance with OPNAVINST 5510.161.\r6.3 Notice To Distributors/Offerors - Consideration for award of contract shall be given only to authorized distributors of the original manufacturer's item represented in this solicitation. If you desire to be considered as a potential source for award of\rthis contract, proof of being an authorized distributor shall be provided on company letterhead signed by a responsible company official and sent with your offer to the Procurement Contracting Officer.\r"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
LAPTOP,ALTERED tender | Tenqual