4140--AIRFLOW CERTIFICATION SAINT LOUIS VA MEDICAL CENTERS JOHN COCHREN & JEFFERSON BARRACKS 36C25526Q0189

Country
United States
Published
February 9, 2026
Deadline
February 27, 2026

Description

{"description":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.\nAll information received in response to this RFI that is marked as proprietary will be handled accordingly.\nResponses to this notice are not offers and cannot be accepted by the Government to form a binding\ncontract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly\nencouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources\nsought/RFI is to gain knowledge of potential qualified sources and their size classification relative to\nNAICS 238220. Responses to this sources sought will be used by the Government to make appropriate\nacquisition decisions. After review of the responses to this sources sought, a solicitation announcement\nmay be published. Responses to this sources sought synopsis are not considered adequate responses\nfor a solicitation announcement.\n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that\ncan provide the following:\n\nAnnual Airflow Certification for the Saint Louis VA Medical Center John Crochan at 915 North Grand Blvd Saint Louis, MO 63106 and Jefferson Barracks at 1 Jefferson Barracks Drive Saint Louis, MO 63125.\n\n\nIt is the responsibility of the interested source to demonstrate to the government that the interested\nparties can provide the supplies/services that fulfill the brand name.\n\nIf you are interested and are capable of providing the sought out supplies/services, please provide the\nrequested information as well as the information indicated below. \n\nResponse to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service\nDisabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone,\nWoman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or\nan equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state\nhow and what is altered; assembled; modified?\n\n Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal\ncontract, that can be utilized to procure the requirement listed above. If so, please provide the contract\nnumber.\n\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW.\n\nPlease provide your SAM s UEI number.\n\nResponses to this notice shall be submitted via email to Lisa Fischer at Lisa.Fischer1@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday February 27th, 2026, by 1500 PM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\n\n\nDEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER\nJOHN COCHRAN AND JEFFERSON BARRACKS STL VAMC \n\nPERFORMANCE WORK STATEMENT (PWS)\n\nAir Changes per Hour (ACH) Certification\n\nSt. Louis VA Health Care System John Cochran and Jefferson Barracks Divisions \n\n1. General\nThe St. Louis VA Health Care System (VASTLHCS), including the John Cochran and Jefferson Barracks Divisions, requires annual Air Changes per Hour (ACH) certification testing of the HVAC systems and components serving defined spaces in Building 1 at the John Cochran Division and Buildings 53 and 55 at the Jefferson Barracks Division. The purpose of this testing is to verify that ventilation performance and pressure relationships meet applicable VA, industry, and accreditation standards for patient care and support areas. \n\nThe annual certification shall:\nMeasure the air volume supplied to and/or exhausted from each defined space and calculate ACH.\nEvaluate duct leakage (airtightness) where applicable.\nVerify required pressure differentials between spaces.\nIdentify areas that do not meet minimum ACH or pressure requirements and recommend corrective actions. \n\nAll work shall comply with, at a minimum:\nASHRAE 170-2013 (Addendum k), Ventilation of Health Care Facilities.\nVHA Directive 1116(2), Sterile Processing Services (SPS).\nVA Office of Construction & Facilities Management Design Manuals (PG-18-10).\nThe Joint Commission, ventilation, air filtration, and air changes in critical areas (Standard EC.02.05.01 EP15).\nApplicable NFPA and OSHA requirements. \n\n2. Background\nSt. Louis VASTLHCS is an integrated healthcare system consisting of medical centers and community-based outpatient clinics. Services under this PWS will be performed at the main medical center campuses listed herein; any contractor travel costs are the responsibility of the contractor. \n\nThe Government reserves the right to add, remove, or modify locations and facilities as mission requirements evolve within the health care system. The contractor shall accommodate such changes within the scope of the contract, with any corresponding pricing or schedule adjustments processed through formal contract modification. \n\n3. Place of Performance\nACH certification is required at the following locations: \nJohn Cochran Division\n915 N. Grand Blvd., St. Louis, MO 63106\nBuilding 1\nJefferson Barracks Division\n1 Jefferson Barracks Dr., St. Louis, MO 63125\nBuildings 53 and 55 \n\n4. Frequency of Service\nServices shall be performed annually, or as otherwise directed in writing by the Contracting Officer (CO). \n\n5. Areas to be Tested\nThe estimated rooms and spaces to be tested, including required pressure relationships and minimum ACH, are listed in Table 1 for John Cochran and Jefferson Barracks. These lists are estimates for planning and pricing purposes; the Government may adjust specific rooms or add comparable spaces during the contract period of performance by written direction of the CO or COR. \n\nTable 1 Representative Rooms for ACH Certification\n(John Cochran and Jefferson Barracks ORs, isolation rooms, ante rooms, pharmacy USP 797/800 areas, cardiac cath labs, bronchoscopy suites, Endo/GI labs, and related critical spaces, with indicated positive/negative pressure and required ACH values.) \n\nJohn Cochran\n\n\nFloor\nRoom\nAir Pressure\nAir Change Required\nBasement\nCB24 Surgical Storage \nPositive\n4\nBasement\nCB26\nPositive\n10\nBasement\nCB16 Decontamination\nNegative\n10\nBasement\nCB29 Case Cart Storage\nPositive\n4\n1st Floor\nE128 Isolation Room\nNegative\n12\n1st Floor\nB124 Cystoscopy\nPositive\n15\n2nd Floor\nA261 Radiology\nPositive\n15\n2nd Floor\nD220 ABG \nNegative\n12\n2nd Floor\nD219 Ante Room\nNegative\n12\n4th Floor\nOR 1\nPositive\n20\n4th Floor\nOR 2\nPositive\n20\n4th Floor\nOR 3\nPositive\n20\n4th Floor\nOR 4\nPositive\n20\n4th Floor\nOR 5\nPositive\n20\n4th Floor\nOR 6\nPositive\n20\n4th Floor\nOR 7\nPositive\n20\n4th Floor\nOR 8\nPositive\n20\n4th Floor\nOR 9\nPositive\n20\n4th Floor\nOR 10\nPositive\n20\n4th Floor\nOR 11\nPositive\n20\n4th Floor\nOR 12\nPositive\n20\n4th Floor\nOR 13\nPositive\n20\n4th Floor\nOR 14\nPositive\n20\n4th Floor\nA440 Pharmacy Ante Room\nPositive\n30\n4th Floor\nA440A Pharmacy Mixing Room\nPositive\n30\n4th Floor\nA452 USP 800 HD Buffer\nPositive\n30\n4th Floor\nA452A Ante\nNegative\n30\n4th Floor\nA453 USP 800 Storage\nNegative\n30\n4th Floor\nA456A USP 800 HD Storage\nNegative\n30\n4th Floor\nA457 Ante\nPositive\n30\n4th Floor\nA457A USP 800 HD Buffer\nNegative\n30\n4th Floor\nA457B USP 800 Non-HD Buffer\nPositive\n30\n4th Floor\nC403 Isolation Room\nNegative\n12\n4th Floor\nC405 Isolation Room\nNegative\n12\n5th Floor\nB524 EP Lab\nPositive\n8\n5th Floor\nB509 Cardiac Cath Lab\nPositive\n15\n5th Floor\nB516 Cardiac Cath Lab\nPositive\n15\n5th Floor\nC512 Brochosccopy Suite\nNegative\n12\n6th Floor\nA608 Endo/GI Lab\nNegative\n12\n6th Floor\nA609 Endo/GI Lab\nNegative\n12\n6th Floor\nA610 Endo/GI Lab\nNegative\n12\n6th Floor\nA611 Endo/GI Lab\nNegative\n12\n6th Floor\nA612 Endo/GI Lab\nNegative\n12\n6th Floor\nA663 Isolation Room\nNegative\n12\n6th Floor\nA658 Isolation Room\nNegative\n12\n6th Floor\nC602 Isolation Room\nNegative\n12\n6th Floor\nC605 Isolation Room\nNegative\n12\n6th Floor\nC615 Isolation Room\nNegative\n12\n7th Floor\nA707 Isoaltion Room\nNegative\n12\n7th Floor\nA720 Isolation Room\nNegative\n12\n7th Floor\nA757 Isolation Room\nNegative\n12\n7th Floor\nB705 Isolation Room\nNegative\n12\n\n Jefferson Barracks\nBuilding\nRoom\nAir Pressure\nAir Change Required\n53\n1N118 Ante room\nPositive\n10\n53\n1N121 Isolation room\nNegative\n12\n53\n1S17 Ante room\nPositive\n10\n53\n1S18 Isolation room\nNegative\n12\n53\n2S29 Ante room\nPositive\n10\n53\n2S30 Isolation room\nNegative\n12\n55\n1C26 / USP 797 Ante Room\nPositive\n20\n55\n1C26A / USP 797 Buffer Room\nPositive\n30\n\nThe contractor shall:\nVerify the spaces actually served by the systems under test.\nTest all rooms listed in the final, Government-approved room list each year.\nNote any inaccessible or out-of-service spaces and explain in the report. \n\n6. Days and Hours of Operation\nNormal hours of performance are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding Federal holidays. Due to clinical needs, portions of the work may be required during evenings, nights, or weekends; such work shall be coordinated in advance with the COR. \nThe contractor shall coordinate all access to occupied clinical areas (e.g., ORs, isolation rooms, Endo/GI) so that testing minimizes impact to patient care and complies with infection control requirements. \n\n7. Contractor Qualifications and Certifications\nThe contractor shall:\nHave significant experience performing ACH and ventilation testing in large medical centers or comparable complex facilities.\nBe an accredited Testing, Adjusting and Balancing Bureau (TABB)-certified firm for the testing performed under this contract.\nHold a valid Class A Air Conditioning and Refrigeration Contractor s (ACR) license with appropriate endorsements, as required by jurisdiction.\nUtilize a TABB-certified supervisor and TABB-certified technicians to perform field work. \nThe contractor shall not subcontract labor and supervision without prior written approval from the CO. If subcontractors are used, their qualifications and certifications shall meet the same requirements as those of the prime contractor s personnel performing similar work. \n\n8. Performance Requirements\nThe contractor shall provide all labor, materials, instruments, equipment, supervision, and incidentals necessary to perform annual ACH testing and certification for the identified HVAC systems and spaces. At a minimum, the contractor shall: \nMeasure airflow (supply, return, exhaust as applicable) for each designated space using calibrated instruments and accepted NEBB or AABC procedures.\nCalculate ACH for each space based on measured airflow and room volume.\nVerify pressure relationships (positive/negative/neutral) relative to adjacent spaces using appropriate differential pressure measurement.\nCompare measured results to required design values and applicable codes/standards.\nIdentify any deficiencies (e.g., ACH below minimum, incorrect pressure relationship, excessive variance from design).\nProvide recommendations to correct deficiencies (e.g., damper adjustments, balancing, control changes, or design review), recognizing that corrective work itself is outside the scope unless separately ordered. \n\nTesting and certification shall be conducted in accordance with:\nASHRAE 170-2013 (Addendum k).\nThe design criteria for the existing HVAC system and relevant VA design standards.\nCurrent NEBB or AABC Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. \n\n9. Infection Control and Housekeeping\nInfection control is critical in all medical center facilities. The contractor shall: \nFollow VA infection prevention and control policies, including use of barriers, containment methods, and cleaning procedures as directed by the facility.\nMinimize dust and airborne particles during testing activities.\nRemove any dust and debris generated by testing and leave work areas in a clean condition acceptable to the COR. \n\n10. Special Contract Requirements\nThe contractor shall provide a brief company profile that includes full legal name, primary and branch office locations, years in business, and description of relevant services. The contractor shall maintain an effective contingency plan to ensure uninterrupted performance (e.g., backup personnel, equipment, and scheduling strategies) at no additional cost to the Government. \nThe contractor is responsible for supervising subcontractors and suppliers and ensuring contract compliance. Any changes to proposed subcontractors or key suppliers shall be submitted to the CO at least thirty (30) days prior to implementation, along with any required licenses, permits, or certifications. \n\n11. Contractor Personnel and Key Personnel\nThe contractor shall designate a contract manager/project manager who has full authority to act for the contractor on all matters relating to daily operation of this contract. The contractor shall provide the name and contact information (during and after hours) for the contract manager and at least one alternate in writing to the CO. \nAll contractor employees:\nShall wear appropriate personal protective equipment (PPE) required by OSHA, VA policy, and the nature of the work.\nShall wear visible identification badges while on VA property.\nShall receive training necessary to safely and competently perform the required tasks. \n\nAny changes in contract manager or other designated key personnel shall be provided in writing to the CO at least forty-eight (48) hours prior to the change, or as soon as practicable in emergencies. \n\n12. Safety, Health, and Protection of Property\nThe contractor shall be fully responsible for the safety of its personnel and protection of Government property during performance. The contractor shall: \nComply with all applicable Federal, State, and local safety and health laws and regulations, including OSHA.\nTake necessary precautions to protect patients, visitors, staff, and property at each location.\nRepair or reimburse the Government for any damage to buildings, finishes, or equipment resulting from contractor operations, including painting, refinishing, or replacement as needed. \n\nThe contractor agrees that personnel and equipment are subject to safety inspections by Government personnel while on VA property. \n\n13. Permits and Licenses\nWithout additional expense to the Government, the contractor shall obtain and maintain all licenses, permits, and approvals required to perform the work described in this PWS. The contractor shall ensure compliance with all applicable Federal, State, and municipal codes and regulations. \n\n14. Quality Assurance\nThe contractor shall implement a Quality Assurance plan appropriate to the scope and risk of the work. The plan shall describe: \nInternal procedures to ensure that testing methods, measurements, and calculations are accurate and repeatable.\nInstrument calibration practices and records.\nInternal review of reports before submission.\nMeasures used to ensure timely completion and responsiveness to VA inquiries. \n\nThe Government may monitor performance through report reviews, field observations, and other surveillance methods, and may require corrective action if quality standards are not met. \n\n15. Communication and Project Management\nThe contractor shall maintain effective communication with the COR and other designated VA staff throughout the period of performance. At a minimum, the contractor shall: \nBe capable of sending and receiving email and participating in phone or virtual meetings.\nCoordinate schedules, access requirements, and infection control measures in advance.\nPromptly communicate any conditions that may delay testing or affect patient care areas. \n\nThe project management approach shall identify the contractor s organizational structure for this contract, including roles, responsibilities, and escalation procedures for resolving technical or performance issues. \n\n16. Reports\nThe contractor shall submit a separate, detailed ACH report for each location to VA Engineering no later than two (2) weeks after completion of testing at that location. Each report shall, at a minimum, include: \nReport title and date.\nCertification statement, including signature of the responsible TABB professional.\nTable of contents.\nExecutive summary and remarks.\nList of test instruments with calibration information.\nAbbreviations and definitions used.\nDetailed tabulated results for each room/space (measured airflows, calculated ACH, required ACH, required pressure relationship, measured pressure differential, and pass/fail indication).\nDescription of any deviations from NEBB or AABC standard procedures, if applicable. \n\nThe report shall:\nReflect system measurements obtained in accordance with current NEBB or AABC standards.\nNote any variances from design quantities that exceed NEBB or AABC tolerances.\nClearly identify deficiencies and provide recommended corrective actions.\nInclude narrative notes and comments as needed to explain system conditions and test results. \n\n17. Capabilities and Relevant Experience (For Proposal Instructions, if used with an RFQ/RFP)\nIf this PWS is used in a solicitation, offerors may be required to provide:\nA description of corporate capabilities to perform ACH testing in large medical facilities.\nPast performance information for at least three relevant contracts completed within the last two years, including points of contact, contract numbers, contract type, dollar value, dates, and brief work descriptions. \n\n18. Administration\n\n18.1 Facility Orientation\nThe COR will provide an initial orientation of the facility and applicable procedures at the start of the contract. The contractor shall orient any new employees thereafter in facility-specific requirements, including safety, security, and infection control. \n\n18.2 Accident Reporting\nIn the event of an accident on VA property or involving Government personnel or property, the contractor shall immediately notify VA Police and the COR. A written report shall be provided to the CO and COR and include: \nDate and time of occurrence.\nLocation.\nPersonnel involved.\nDescription of events and circumstances in chronological order.\nCorrective action to prevent recurrence. \n\n18.3 Federal Holidays\nWork requiring VA staff support or access to certain areas may not be scheduled on Federal holidays unless specifically approved by the COR. Recognized holidays include New Year s Day, Martin Luther King Jr. Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day. \n\n18.4 Invoices\nPayment will be made no later than thirty (30) days after receipt of a proper invoice, validated by the COR, and submitted via the VA s designated electronic invoicing system. A proper invoice shall include: \nInvoice number and date.\nContractor s name and address.\nValid purchase order or contract number.\nDates services were performed.\nLocation(s) of service.\nTotal amount due, with any required supporting detail. \n\n19. Contracting Officer s Representative (COR)\nThe COR will be designated in the contract award document. A sample COR designation is: \nName: TBD\nTitle: \n\nThe COR is responsible for technical oversight and monitoring of performance but is not authorized to change the terms and conditions of the contract. \n\n\n\n"} Solicitation Number: 36C25526Q0189 Type: Sources Sought Base Type: Sources Sought NAICS: 238220 Classification Code: 4140 Response Deadline: 2026-02-27T15:00:00-06:00 Office Address: LEAVENWORTH, KS Place of Performance: Saint Louis, MO, 63106 POC: CONTRACTING SPECIALIST: LISA FISCHER, Lisa.Fischer1@va.gov, 913-946-1993 {"description":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.\nAll information received in response to this RFI that is marked as proprietary will be handled accordingly.\nResponses to this notice are not offers and cannot be accepted by the Government to form a binding\ncontract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly\nencouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources\nsought/RFI is to gain knowledge of potential qualified sources and their size classification relative to\nNAICS 238220. Responses to this sources sought will be used by the Government to make appropriate\nacquisition decisions. After review of the responses to this sources sought, a solicitation announcement\nmay be published. Responses to this sources sought synopsis are not considered adequate responses\nfor a solicitation announcement.\n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that\ncan provide the following:\n\nAnnual Airflow Certification for the Saint Louis VA Medical Center John Crochan at 915 North Grand Blvd Saint Louis, MO 63106 and Jefferson Barracks at 1 Jefferson Barracks Drive Saint Louis, MO 63125.\n\n\nIt is the responsibility of the interested source to demonstrate to the government that the interested\nparties can provide the supplies/services that fulfill the brand name.\n\nIf you are interested and are capable of providing the sought out supplies/services, please provide the\nrequested information as well as the information indicated below. \n\nResponse to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service\nDisabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone,\nWoman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or\nan equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state\nhow and what is altered; assembled; modified?\n\n Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal\ncontract, that can be utilized to procure the requirement listed above. If so, please provide the contract\nnumber.\n\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW.\n\nPlease provide your SAM s UEI number.\n\nResponses to this notice shall be submitted via email to Lisa Fischer at Lisa.Fischer1@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday February 27th, 2026, by 1500 PM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\n\n\nDEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER\nJOHN COCHRAN AND JEFFERSON BARRACKS STL VAMC \n\nPERFORMANCE WORK STATEMENT (PWS)\n\nAir Changes per Hour (ACH) Certification\n\nSt. Louis VA Health Care System John Cochran and Jefferson Barracks Divisions \n\n1. General\nThe St. Louis VA Health Care System (VASTLHCS), including the John Cochran and Jefferson Barracks Divisions, requires annual Air Changes per Hour (ACH) certification testing of the HVAC systems and components serving defined spaces in Building 1 at the John Cochran Division and Buildings 53 and 55 at the Jefferson Barracks Division. The purpose of this testing is to verify that ventilation performance and pressure relationships meet applicable VA, industry, and accreditation standards for patient care and support areas. \n\nThe annual certification shall:\nMeasure the air volume supplied to and/or exhausted from each defined space and calculate ACH.\nEvaluate duct leakage (airtightness) where applicable.\nVerify required pressure differentials between spaces.\nIdentify areas that do not meet minimum ACH or pressure requirements and recommend corrective actions. \n\nAll work shall comply with, at a minimum:\nASHRAE 170-2013 (Addendum k), Ventilation of Health Care Facilities.\nVHA Directive 1116(2), Sterile Processing Services (SPS).\nVA Office of Construction & Facilities Management Design Manuals (PG-18-10).\nThe Joint Commission, ventilation, air filtration, and air changes in critical areas (Standard EC.02.05.01 EP15).\nApplicable NFPA and OSHA requirements. \n\n2. Background\nSt. Louis VASTLHCS is an integrated healthcare system consisting of medical centers and community-based outpatient clinics. Services under this PWS will be performed at the main medical center campuses listed herein; any contractor travel costs are the responsibility of the contractor. \n\nThe Government reserves the right to add, remove, or modify locations and facilities as mission requirements evolve within the health care system. The contractor shall accommodate such changes within the scope of the contract, with any corresponding pricing or schedule adjustments processed through formal contract modification. \n\n3. Place of Performance\nACH certification is required at the following locations: \nJohn Cochran Division\n915 N. Grand Blvd., St. Louis, MO 63106\nBuilding 1\nJefferson Barracks Division\n1 Jefferson Barracks Dr., St. Louis, MO 63125\nBuildings 53 and 55 \n\n4. Frequency of Service\nServices shall be performed annually, or as otherwise directed in writing by the Contracting Officer (CO). \n\n5. Areas to be Tested\nThe estimated rooms and spaces to be tested, including required pressure relationships and minimum ACH, are listed in Table 1 for John Cochran and Jefferson Barracks. These lists are estimates for planning and pricing purposes; the Government may adjust specific rooms or add comparable spaces during the contract period of performance by written direction of the CO or COR. \n\nTable 1 Representative Rooms for ACH Certification\n(John Cochran and Jefferson Barracks ORs, isolation rooms, ante rooms, pharmacy USP 797/800 areas, cardiac cath labs, bronchoscopy suites, Endo/GI labs, and related critical spaces, with indicated positive/negative pressure and required ACH values.) \n\nJohn Cochran\n\n\nFloor\nRoom\nAir Pressure\nAir Change Required\nBasement\nCB24 Surgical Storage \nPositive\n4\nBasement\nCB26\nPositive\n10\nBasement\nCB16 Decontamination\nNegative\n10\nBasement\nCB29 Case Cart Storage\nPositive\n4\n1st Floor\nE128 Isolation Room\nNegative\n12\n1st Floor\nB124 Cystoscopy\nPositive\n15\n2nd Floor\nA261 Radiology\nPositive\n15\n2nd Floor\nD220 ABG \nNegative\n12\n2nd Floor\nD219 Ante Room\nNegative\n12\n4th Floor\nOR 1\nPositive\n20\n4th Floor\nOR 2\nPositive\n20\n4th Floor\nOR 3\nPositive\n20\n4th Floor\nOR 4\nPositive\n20\n4th Floor\nOR 5\nPositive\n20\n4th Floor\nOR 6\nPositive\n20\n4th Floor\nOR 7\nPositive\n20\n4th Floor\nOR 8\nPositive\n20\n4th Floor\nOR 9\nPositive\n20\n4th Floor\nOR 10\nPositive\n20\n4th Floor\nOR 11\nPositive\n20\n4th Floor\nOR 12\nPositive\n20\n4th Floor\nOR 13\nPositive\n20\n4th Floor\nOR 14\nPositive\n20\n4th Floor\nA440 Pharmacy Ante Room\nPositive\n30\n4th Floor\nA440A Pharmacy Mixing Room\nPositive\n30\n4th Floor\nA452 USP 800 HD Buffer\nPositive\n30\n4th Floor\nA452A Ante\nNegative\n30\n4th Floor\nA453 USP 800 Storage\nNegative\n30\n4th Floor\nA456A USP 800 HD Storage\nNegative\n30\n4th Floor\nA457 Ante\nPositive\n30\n4th Floor\nA457A USP 800 HD Buffer\nNegative\n30\n4th Floor\nA457B USP 800 Non-HD Buffer\nPositive\n30\n4th Floor\nC403 Isolation Room\nNegative\n12\n4th Floor\nC405 Isolation Room\nNegative\n12\n5th Floor\nB524 EP Lab\nPositive\n8\n5th Floor\nB509 Cardiac Cath Lab\nPositive\n15\n5th Floor\nB516 Cardiac Cath Lab\nPositive\n15\n5th Floor\nC512 Brochosccopy Suite\nNegative\n12\n6th Floor\nA608 Endo/GI Lab\nNegative\n12\n6th Floor\nA609 Endo/GI Lab\nNegative\n12\n6th Floor\nA610 Endo/GI Lab\nNegative\n12\n6th Floor\nA611 Endo/GI Lab\nNegative\n12\n6th Floor\nA612 Endo/GI Lab\nNegative\n12\n6th Floor\nA663 Isolation Room\nNegative\n12\n6th Floor\nA658 Isolation Room\nNegative\n12\n6th Floor\nC602 Isolation Room\nNegative\n12\n6th Floor\nC605 Isolation Room\nNegative\n12\n6th Floor\nC615 Isolation Room\nNegative\n12\n7th Floor\nA707 Isoaltion Room\nNegative\n12\n7th Floor\nA720 Isolation Room\nNegative\n12\n7th Floor\nA757 Isolation Room\nNegative\n12\n7th Floor\nB705 Isolation Room\nNegative\n12\n\n Jefferson Barracks\nBuilding\nRoom\nAir Pressure\nAir Change Required\n53\n1N118 Ante room\nPositive\n10\n53\n1N121 Isolation room\nNegative\n12\n53\n1S17 Ante room\nPositive\n10\n53\n1S18 Isolation room\nNegative\n12\n53\n2S29 Ante room\nPositive\n10\n53\n2S30 Isolation room\nNegative\n12\n55\n1C26 / USP 797 Ante Room\nPositive\n20\n55\n1C26A / USP 797 Buffer Room\nPositive\n30\n\nThe contractor shall:\nVerify the spaces actually served by the systems under test.\nTest all rooms listed in the final, Government-approved room list each year.\nNote any inaccessible or out-of-service spaces and explain in the report. \n\n6. Days and Hours of Operation\nNormal hours of performance are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding Federal holidays. Due to clinical needs, portions of the work may be required during evenings, nights, or weekends; such work shall be coordinated in advance with the COR. \nThe contractor shall coordinate all access to occupied clinical areas (e.g., ORs, isolation rooms, Endo/GI) so that testing minimizes impact to patient care and complies with infection control requirements. \n\n7. Contractor Qualifications and Certifications\nThe contractor shall:\nHave significant experience performing ACH and ventilation testing in large medical centers or comparable complex facilities.\nBe an accredited Testing, Adjusting and Balancing Bureau (TABB)-certified firm for the testing performed under this contract.\nHold a valid Class A Air Conditioning and Refrigeration Contractor s (ACR) license with appropriate endorsements, as required by jurisdiction.\nUtilize a TABB-certified supervisor and TABB-certified technicians to perform field work. \nThe contractor shall not subcontract labor and supervision without prior written approval from the CO. If subcontractors are used, their qualifications and certifications shall meet the same requirements as those of the prime contractor s personnel performing similar work. \n\n8. Performance Requirements\nThe contractor shall provide all labor, materials, instruments, equipment, supervision, and incidentals necessary to perform annual ACH testing and certification for the identified HVAC systems and spaces. At a minimum, the contractor shall: \nMeasure airflow (supply, return, exhaust as applicable) for each designated space using calibrated instruments and accepted NEBB or AABC procedures.\nCalculate ACH for each space based on measured airflow and room volume.\nVerify pressure relationships (positive/negative/neutral) relative to adjacent spaces using appropriate differential pressure measurement.\nCompare measured results to required design values and applicable codes/standards.\nIdentify any deficiencies (e.g., ACH below minimum, incorrect pressure relationship, excessive variance from design).\nProvide recommendations to correct deficiencies (e.g., damper adjustments, balancing, control changes, or design review), recognizing that corrective work itself is outside the scope unless separately ordered. \n\nTesting and certification shall be conducted in accordance with:\nASHRAE 170-2013 (Addendum k).\nThe design criteria for the existing HVAC system and relevant VA design standards.\nCurrent NEBB or AABC Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. \n\n9. Infection Control and Housekeeping\nInfection control is critical in all medical center facilities. The contractor shall: \nFollow VA infection prevention and control policies, including use of barriers, containment methods, and cleaning procedures as directed by the facility.\nMinimize dust and airborne particles during testing activities.\nRemove any dust and debris generated by testing and leave work areas in a clean condition acceptable to the COR. \n\n10. Special Contract Requirements\nThe contractor shall provide a brief company profile that includes full legal name, primary and branch office locations, years in business, and description of relevant services. The contractor shall maintain an effective contingency plan to ensure uninterrupted performance (e.g., backup personnel, equipment, and scheduling strategies) at no additional cost to the Government. \nThe contractor is responsible for supervising subcontractors and suppliers and ensuring contract compliance. Any changes to proposed subcontractors or key suppliers shall be submitted to the CO at least thirty (30) days prior to implementation, along with any required licenses, permits, or certifications. \n\n11. Contractor Personnel and Key Personnel\nThe contractor shall designate a contract manager/project manager who has full authority to act for the contractor on all matters relating to daily operation of this contract. The contractor shall provide the name and contact information (during and after hours) for the contract manager and at least one alternate in writing to the CO. \nAll contractor employees:\nShall wear appropriate personal protective equipment (PPE) required by OSHA, VA policy, and the nature of the work.\nShall wear visible identification badges while on VA property.\nShall receive training necessary to safely and competently perform the required tasks. \n\nAny changes in contract manager or other designated key personnel shall be provided in writing to the CO at least forty-eight (48) hours prior to the change, or as soon as practicable in emergencies. \n\n12. Safety, Health, and Protection of Property\nThe contractor shall be fully responsible for the safety of its personnel and protection of Government property during performance. The contractor shall: \nComply with all applicable Federal, State, and local safety and health laws and regulations, including OSHA.\nTake necessary precautions to protect patients, visitors, staff, and property at each location.\nRepair or reimburse the Government for any damage to buildings, finishes, or equipment resulting from contractor operations, including painting, refinishing, or replacement as needed. \n\nThe contractor agrees that personnel and equipment are subject to safety inspections by Government personnel while on VA property. \n\n13. Permits and Licenses\nWithout additional expense to the Government, the contractor shall obtain and maintain all licenses, permits, and approvals required to perform the work described in this PWS. The contractor shall ensure compliance with all applicable Federal, State, and municipal codes and regulations. \n\n14. Quality Assurance\nThe contractor shall implement a Quality Assurance plan appropriate to the scope and risk of the work. The plan shall describe: \nInternal procedures to ensure that testing methods, measurements, and calculations are accurate and repeatable.\nInstrument calibration practices and records.\nInternal review of reports before submission.\nMeasures used to ensure timely completion and responsiveness to VA inquiries. \n\nThe Government may monitor performance through report reviews, field observations, and other surveillance methods, and may require corrective action if quality standards are not met. \n\n15. Communication and Project Management\nThe contractor shall maintain effective communication with the COR and other designated VA staff throughout the period of performance. At a minimum, the contractor shall: \nBe capable of sending and receiving email and participating in phone or virtual meetings.\nCoordinate schedules, access requirements, and infection control measures in advance.\nPromptly communicate any conditions that may delay testing or affect patient care areas. \n\nThe project management approach shall identify the contractor s organizational structure for this contract, including roles, responsibilities, and escalation procedures for resolving technical or performance issues. \n\n16. Reports\nThe contractor shall submit a separate, detailed ACH report for each location to VA Engineering no later than two (2) weeks after completion of testing at that location. Each report shall, at a minimum, include: \nReport title and date.\nCertification statement, including signature of the responsible TABB professional.\nTable of contents.\nExecutive summary and remarks.\nList of test instruments with calibration information.\nAbbreviations and definitions used.\nDetailed tabulated results for each room/space (measured airflows, calculated ACH, required ACH, required pressure relationship, measured pressure differential, and pass/fail indication).\nDescription of any deviations from NEBB or AABC standard procedures, if applicable. \n\nThe report shall:\nReflect system measurements obtained in accordance with current NEBB or AABC standards.\nNote any variances from design quantities that exceed NEBB or AABC tolerances.\nClearly identify deficiencies and provide recommended corrective actions.\nInclude narrative notes and comments as needed to explain system conditions and test results. \n\n17. Capabilities and Relevant Experience (For Proposal Instructions, if used with an RFQ/RFP)\nIf this PWS is used in a solicitation, offerors may be required to provide:\nA description of corporate capabilities to perform ACH testing in large medical facilities.\nPast performance information for at least three relevant contracts completed within the last two years, including points of contact, contract numbers, contract type, dollar value, dates, and brief work descriptions. \n\n18. Administration\n\n18.1 Facility Orientation\nThe COR will provide an initial orientation of the facility and applicable procedures at the start of the contract. The contractor shall orient any new employees thereafter in facility-specific requirements, including safety, security, and infection control. \n\n18.2 Accident Reporting\nIn the event of an accident on VA property or involving Government personnel or property, the contractor shall immediately notify VA Police and the COR. A written report shall be provided to the CO and COR and include: \nDate and time of occurrence.\nLocation.\nPersonnel involved.\nDescription of events and circumstances in chronological order.\nCorrective action to prevent recurrence. \n\n18.3 Federal Holidays\nWork requiring VA staff support or access to certain areas may not be scheduled on Federal holidays unless specifically approved by the COR. Recognized holidays include New Year s Day, Martin Luther King Jr. Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day. \n\n18.4 Invoices\nPayment will be made no later than thirty (30) days after receipt of a proper invoice, validated by the COR, and submitted via the VA s designated electronic invoicing system. A proper invoice shall include: \nInvoice number and date.\nContractor s name and address.\nValid purchase order or contract number.\nDates services were performed.\nLocation(s) of service.\nTotal amount due, with any required supporting detail. \n\n19. Contracting Officer s Representative (COR)\nThe COR will be designated in the contract award document. A sample COR designation is: \nName: TBD\nTitle: \n\nThe COR is responsible for technical oversight and monitoring of performance but is not authorized to change the terms and conditions of the contract. \n\n\n\n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
4140--AIRFLOW CERTIFICATION SAINT LOUIS VA MEDICAL CENTERS JOHN COCHREN & JEFFERSON BARRACKS 36C25526Q0189 tender | Tenqual