Back to search
SAM.govNotice 83d019ce7aeb4447a2a70bf2fbc24571

6515--Humidifier heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater Wire Adapter Sources Sought

Country
United States
Published
February 4, 2026
Deadline
February 12, 2026

Description

{"description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: Small Businesses to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL.\n\nGeneral Requirements:\n\nBrand Name or Equal\n\nThe below products are known to meet the governments needs all equal parts will be considered.\n \n950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal\n\nSalient Characteristics:\n\nTherapy Profiles:\nMust support Invasive ventilation\nMust support Noninvasive ventilation\nMust support Nasal High Flow therapy.\n\nTemperature Probes:\nMust have no external temperature probes\nMust incorporate internal temperature probes that do not require special disinfection processing\n\nCircuit Compatibility:\nMust be compatible with single heated circuits for non-invasive ventilation.\nMust be compatible with double heated circuits for invasive ventilation.\n\nUser Interface:\nMust have a simple user interface\nMust include touch screen monitors to create setting modifications\nMust allow mode changes\nMust allow comfort setting adjustments\nMust display and troubleshoot alarms\nMust provide access to Information and Service menus\n\nAlarms:\nMust have built-in alarms for various conditions including but not limited to:\n1. High Temperature alarms\n2. Low Temperature alarms\n3. Water Out alarms\n4. Circuit Disconnect alarms\n5. Reverse Gas Flow alarms\n6. System check alarms\n\nCompatibility:\nMust be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC,\nSpecifically, it must be compatible with Medtronic 980 ventilators\nSpecifically, it must be compatible with Philips V60 BiPAP devices\nSpecifically, it must be compatible with Nihon Kohden 330, 440, and 550 ventilator systems All interested firms who can meet the requirements stated above should respond, in writing,\n\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\n\n\nSubmit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 4:00 PM (Central Standard Time), 12 February 2026.\n\n36C25226Q0244 950 Humidifier Heater base shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.\n\n\n"} Solicitation Number: 36C25226Q0244 Type: Sources Sought Base Type: Sources Sought NAICS: 339112 Classification Code: 6515 Response Deadline: 2026-02-12T16:00:00-06:00 Office Address: MILWAUKEE, WI POC: Ryan Nugent, Ryan.Nugent@va.gov, 414-844-4800 {"description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: Small Businesses to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL.\n\nGeneral Requirements:\n\nBrand Name or Equal\n\nThe below products are known to meet the governments needs all equal parts will be considered.\n \n950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal\n\nSalient Characteristics:\n\nTherapy Profiles:\nMust support Invasive ventilation\nMust support Noninvasive ventilation\nMust support Nasal High Flow therapy.\n\nTemperature Probes:\nMust have no external temperature probes\nMust incorporate internal temperature probes that do not require special disinfection processing\n\nCircuit Compatibility:\nMust be compatible with single heated circuits for non-invasive ventilation.\nMust be compatible with double heated circuits for invasive ventilation.\n\nUser Interface:\nMust have a simple user interface\nMust include touch screen monitors to create setting modifications\nMust allow mode changes\nMust allow comfort setting adjustments\nMust display and troubleshoot alarms\nMust provide access to Information and Service menus\n\nAlarms:\nMust have built-in alarms for various conditions including but not limited to:\n1. High Temperature alarms\n2. Low Temperature alarms\n3. Water Out alarms\n4. Circuit Disconnect alarms\n5. Reverse Gas Flow alarms\n6. System check alarms\n\nCompatibility:\nMust be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC,\nSpecifically, it must be compatible with Medtronic 980 ventilators\nSpecifically, it must be compatible with Philips V60 BiPAP devices\nSpecifically, it must be compatible with Nihon Kohden 330, 440, and 550 ventilator systems All interested firms who can meet the requirements stated above should respond, in writing,\n\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\n\n\nSubmit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 4:00 PM (Central Standard Time), 12 February 2026.\n\n36C25226Q0244 950 Humidifier Heater base shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.\n\n\n"}

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
6515--Humidifier heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater Wire Adapter Sources Sought tender | Tenqual