Back to search
SAM.govNotice 5e4adde126f642d3a3e109e12a486320

5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS

Country
United States
Published
April 29, 2026
Deadline
May 7, 2026

Description

{"description":"The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of the Fayetteville VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses capable of providing two (2) replacement doors for mental health patients rooms:\nThe contractor shall furnish labor, parts, supplies and equipment necessary to provide and install new 2 Acrovyn Barrier Resistant Doors.\nThe contractor is required to conduct a site visit to gain a complete understanding of the work and requirements that need to be accomplished.\nServices should be performed in accordance with terms and conditions in this statement of work and be in compliance with all manufacturers technical specifications.\nThe estimate dimensions of the existing door: (Width: 43-1/2 Height: 83-1/4 Thickness: 1-3/4 )\nKey Door Requirements for Behavioral Health\nLigature Resistance: All hardware, including handles, hinges, and closures, must be designed to minimize ligature points.\nAnti-Barricade/Access: Doors often feature double-swing hinges or emergency release stops, allowing them to swing outward into the hallway even if they normally swing inward, enabling staff to overcome barricades.\nSafety Features: Use of concealed hinges, continuous gear hinges.\nMonitoring & Security: Doors usually include door-top sensors that alert staff to self-harm attempts.\nDoor Types: Options include \"door within a door\" (wicket) allowing a smaller portion of the door to open for emergency access.\nMaterial: Doors are typically constructed from high-strength materials like fully welded, hollow metal steel frames.\nCompliance and Standards\nNFPA 101-2012: Provides standards on door-locking arrangements in psychiatric units.\nJoint Commission: \nRequires compliance with 2021 Behavioral Health standards, including specific requirements for door gaps (not exceeding 1/8 inch) and undercuts (not exceeding 1 inch) to ensure security and smoke resistance. \nUL (Underwriters Laboratories) Standards: UL 10C for fire door assemblies, ensuring fire resistance and integrity.\nNFPA (National Fire Protection Association): NFPA 80 for fire door assemblies and opening protectives.\nANSI (American National Standards Institute): ANSI/UL 263 for fire resistance testing.\nASTM (American Society for Testing and Materials): Standards related to material performance, such as ASTM E119 for fire testing.\nISO Standards: ISO 300-2007 for fire resistance of building elements, depending on project requirements.\nLocal Building Codes: Compliance with local and national building codes, which may specify performance and safety standards.\n\n\n\n\nAll respondents shall indicate/provide the following:\nWhether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.\nIs your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?\nWhether or not your company has an active SAM registration and the companies Unique Entity Identifier.\nA copy of its capabilities statement.\nFailure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.\nIf the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered capable of meeting the VA s needs.\nThe capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than May 7th, at 3:00PM EST to the attention of: jake.puckett@va.gov \nAll responses shall be submitted as: Sources Sought 36C24626Q0564: Fayetteville VAMC Replacement Doors for Mental Health Patient Rooms.\n"} Solicitation Number: 36C24626Q0564 Type: Sources Sought Base Type: Sources Sought NAICS: 332321 Classification Code: 5670 Response Deadline: 2026-05-07T15:00:00-04:00 Office Address: HAMPTON, VA Place of Performance: Fayetteville, North Carolina, 28301 POC: jake.puckett@va.gov, Jake.Puckett@va.gov

Open original notice

Get tenders like this in one daily alert

Use this notice as context when Tenqual drafts your search scope and fit criteria.

Create free alert
5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS tender | Tenqual