Tenqual homeBrowse public tender search
SAM.gov

UPS MODULE INSTALLATION

Unknown purchaserUnited States

Purchaser

Country

United States

Published

27 Apr 2026

Closing date

4 May 2026

Source ID

Docs found

Create a free account to save this tender

Save this notice and create a tender alert for similar public opportunities.

  • Create one free tender alert.
  • See a short explanation of why each tender matches.
  • Upgrade later when you want help planning and writing the bid.

Tender summary

<p>This is a <strong>COMBINED SYNOPSIS/SOLICITATION </strong>for commercial items prepared in accordance with the information in Federal Acquisition Regulation (FAR) Part 13 using Simplified Acquisition Procedures (SAP). This announcement constitutes the only solicitation; a written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This combined synopsis/solicitation WILL be posted to SAM at https://sam.gov.</p> <p><strong>SOLICITATION NUMBER: </strong>SPMYM126Q4059</p> <p><strong>BUYER: </strong>RONALD MARTIN</p> <p><strong>EMAIL ADDRESS: </strong>ronald.c.martin@dla.mil</p> <p>This solicitation documents and incorporates provisions and clauses in effect though FAC 2025-05 and the DFARS Change notice 08/07/2025. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at this website: https://www.acquisition.gov/.</p> <p>NNSY - Norfolk Naval Shipyard requests responses from qualified sources capable of providing the material that is referenced below. All items shall be new. No refurbished or used items will be accepted. This solicitation is <strong><u>BRAND NAME only, 100% small business set-aside utilizing Lowest Price Technically Acceptable evaluation factors</u></strong>.</p> <p>CLIN NUMBER&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; DESCRIPTION&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; QTY&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; UNIT PRICE&nbsp;&nbsp;&nbsp;&nbsp; TOTAL</p> <p>CLIN 0001</p> <p>60438640&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; UPS MODULE, 250KVA, W/ INTERNAL BYPASS, TOP/BTM 1 ENTRY</p> <p>ONLINE TRUE DOUBLE CONVERSION.</p> <p>Manufacturer: AGSI Systems LLC&nbsp;&nbsp;&nbsp; 1 EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p> <p>CLIN 0002</p> <p>60438641&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; TRANSFORMER CABINET</p> <p>3- PHASE 480V DEL TA - 208 Y120</p> <p>Manufacturer: AGSI Systems LLC&nbsp;&nbsp;&nbsp; 1EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p> <p>CLIN 0003</p> <p>60438642&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; BATTERY CABINET (1) STRING 390W, 400A BREAKER</p> <p>Manufacturer: AGSI Systems LLC&nbsp;&nbsp;&nbsp; 4 EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p> <p><strong>CLIN 0001 <u>SPECIFICATIONS</u></strong>:</p> <p></p> <p>UPS MODULE, 250kva, w/ internal bypass</p> <p>-Top/btm 1 entry online true double conversion.</p> <p>- Advanced circuitry to prevent unexpected failure.</p> <p>- PWM INVERTER utilizing insulated gate bipolar transistor.</p> <p>- PARALLEL UP TO 8 MODULES for capacity or redundancy in single model and group module configurations with optional parallel kit.</p> <p>- Regulated output voltage +/- 1% with balanced load, +/- 3% with 100% unbalanced load.</p> <p>- Menu driven front panel display with sub-menu selections that give complete access to all modes of operation and critical alarm conditions.</p> <p>- Battery cycle monitoring: advanced battery protection and self-test diagnostics that provide the highest level of protection against overheating, deep discharge and low current. Provides detailed BATTERY INFORMATION such as hours of normal operation, hours on bypass, time on battery, number of partial and full discharges for battery warranty validation.</p> <p>- Internal input isolation switch, output isolation switch and system bypass isolation switch.</p> <p>- Automatic continuous duty static bypass.</p> <p>&nbsp;- Remote monitoring with RS 232 serial port and programmable form C dry contacts.</p> <p>- HIGH AC TO AC Efficiency 2 YEAR Full warranty Included</p> <p>REMOVAL-DISPOSAL (NO EXISTING ELECTRICAL-ENVIRONMENT ISSUES)</p> <p>labor and start up included 1 on-site 5 x 8 startup. Startup performed after installation by owner. This includes installation inspection, check-out and activation of</p> <p>THE UPS, instruction of operational personnel and warranty validation. Does not include load bank testing &amp; burn in.</p> <p>Start-up service as included provided.</p> <p>Start-up required for on-site warranty validation.</p> <p></p> <p></p> Solicitation Number: SPMYM126Q4059 Type: Combined Synopsis/Solicitation Base Type: Combined Synopsis/Solicitation NAICS: 541519 Classification Code: 7C21 Response Deadline: 2026-05-04T12:00:00-04:00 Office Address: PORTSMOUTH, VA Place of Performance: Portsmouth, Virginia, 23709 POC: Ronald Martin, ronald.c.martin@dla.mil, 4457373385

What to check before bidding

  • Located in United States.
  • Deadline listed as 4 May 2026.
  • Create a free tender alert to catch similar opportunities before the deadline pressure starts.