Tenqual homeBrowse public tender search
SAM.gov

Cooling Stage

Unknown purchaserUnited States

Purchaser

Country

United States

Published

24 Apr 2026

Closing date

30 Apr 2026

Source ID

Docs found

Create a free account to save this tender

Save this notice and create a tender alert for similar public opportunities.

  • Create one free tender alert.
  • See a short explanation of why each tender matches.
  • Upgrade later when you want help planning and writing the bid.

Summary

<p>SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.</p> <p></p> <p><strong>Please review the quote and provide your best and final offer for both price and lead-time. Kindly also have the quotation revised to today&rsquo;s date and address the quote to my attention. </strong></p> <p></p> <p><strong>The follow has been attached for you to complete and review</strong>:</p> <ol> <li>(BAA) Buy American Act Certification</li> <li>Representations &amp; Certifications Rider</li> <li>Confirm Attached SLAC terms are accepted: FP Commercial Supplies-Services T&amp;Cs (August 2023)</li> </ol> <p><strong>Required item(s) listed below</strong>:</p> <ol> <li>DCS 500 DOMED COOLING STAGE &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>CCU 100 COMBINED CONTROL UNIT&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>LOW-POWER MODULE FOR DCS 500&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>FLOW CONTROL UNIT DCS 500&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>LOW TEMPERATURE EQUIPMENT FOR &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> </ol> <p>VENTURI NOZZLE (DCS)</p> <ol> <li>AIR SERVICE UNIT&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>PEEK DOME DHS&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>GRAPHITE DOME DHS&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &ndash; QTY: 1</li> <li>LIQUID NITROGEN CONTAINER, DEWAR 60L&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&ndash; QTY: 1</li> </ol> <p></p> <p></p> <p>Quote is for product only; no on-site services permitted.</p> <p></p> <p>Source selection will be based on Lowest Price and Technically Acceptable Method (LPTA).</p> <p></p> <p><strong><u>Technical evaluation criteria are as follows: </u></strong></p> <ol> <li> <ol> <li> <ol> <li> <ol> <li><strong>Accessible low temperature (-180 deg C)</strong></li> <li><strong>High Temperature (500 deg C)</strong></li> <li><strong>Compatibility with a 4/6 circle diffractometer goniometer</strong></li> <li><strong>Compatibility with XYZ stages</strong></li> <li><strong>Theta angle from 0-90 degrees</strong></li> <li><strong>Up to 25mm sample size</strong></li> </ol> </li> </ol> </li> </ol> </li> </ol> <p></p> <p>Please provide a price and lead time quotation by COB 4/30/2026.</p> <p><em>Please be advised that the requirement was also posted on SAM.gov.</em></p> <p><strong>Send quote to </strong><strong>marissat@SLAC.stanford.edu</strong><strong>.</strong></p> <p></p> <p>The bid closing date for this requirement is 4/30/2026.</p> <p></p> <p>Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?</p> <p>If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.</p> <p></p> <ul> <li><strong>Buy American Act Certification (BAA)</strong> applies to items that have a unit price that is over $15,000.</li> <li><strong>Representations &amp; Certifications Rider is required</strong>. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.</li> <li><em>Please include in your proposals the <strong>Harmonized Tariff Schedule (HTS Code</strong>) if applicable. </em></li> <li><strong>All subcontractors are required to register in the System for Award Management (</strong><strong>www.sam.gov</strong><strong>).</strong></li> <li><strong>The resulting purchase order will be issued on a fixed price basis.</strong> SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order.</li> <li><strong>Payment Terms will be NET-30 (SLAC is unable to do advance payments and or Prepayments).</strong></li> <li><strong>Freight terms will be FOB Destination Prepaid and Add</strong></li> </ul> <p></p> <p>You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.</p> <p></p> <p>Contact me directly with any questions.</p> <p></p> <p>Kind regards,</p> <p>Marissa Tanomrat</p> <p>Procurement Commodities Team</p> <p>SLAC National Accelerator Laboratory</p> <p>2575 Sand Hill Road</p> <p>Menlo Park, CA 94025</p> <p>Email: marissat@slac.stanford.edu</p> <p></p> Solicitation Number: SLAC_364972_CoolingStage Type: Solicitation Base Type: Solicitation NAICS: 33399 Classification Code: AJ12 Response Deadline: 2026-04-30T17:00:00-07:00 Office Address: Menlo Park, CA Place of Performance: Menlo Park, California, 94025 POC: Katherine Jill A. Coh, kcoh@slac.stanford.edu, 6509262770

Sign in to run AI fit scoring, bid/no bid reviews, and compliance drafting for this tender.

Cooling Stage | Tenqual Tender