Tenqual homeBrowse public tender search
SAM.gov

Pharmacy B201 Chiller One time Repair

Unknown purchaserUnited States

Purchaser

Country

United States

Notice published

2 Dec 2025

Tenqual indexed

4 Dec 2025

Closing date

10 Dec 2025

Source ID

Docs found

Create a free account to save this tender

Save this notice and create a tender alert for similar public opportunities.

  • Create one free tender alert.
  • See a short explanation of why each tender matches.
  • Upgrade later when you want help planning and writing the bid.

Tender summary

The purpose of amendment 0001 is to correct an administrative error in the due date on the solicitation and to comment on industry feedback. Solicitation closes 12/10/2025 at 10:00AM PST. Objective: To provide a complete repair of the Pharmacy Chiller located in Building 201 at the VA Southern Oregon Rehabilitation Center and Clinics (VA SORCC). Tasks: Recover the refrigerant from circuit one of the chiller. Remove the existing Electronic Expansion Valve (EEV) and install a new EEV. Install a new EEV cable from the controller to the new EEV. Install new filter dryers. Conduct a pressure test to check for system leaks. Recharge the system with the recovered refrigerant. Test the entire system to ensure proper functionality. If issues remain unresolved, investigate potential software problems with the chiller. Reprogram the chiller software as necessary to achieve a complete repair. Deliverables: Successful recovery and reuse of refrigerant. Installation of a new EEV and EEV cable. New filter dryers installed. System pressure test results documenting no leaks. System recharge and performance test. Detailed report of any software issues found and actions taken to reprogram the system. VA has already identified these items are among repairs needed, but this is not set out as an exhaustive list, The contractor is responsible for ensuring the chiller operates efficiently and resolving all persistent issues, including any software-related problems. All deliverables must be completed to confirm the repair is thorough and comprehensive. Solicitation Number: 36C260-26-AP-0547 Type: Solicitation Base Type: Solicitation NAICS: 238220 Classification Code: J045 Response Deadline: 2025-12-10T10:00:00-08:00 Office Address: VANCOUVER, WA Place of Performance: White City, Oregon, 97503 POC: Alan C Perez, alan.perez@va.gov POC: Helen Woods, helen.woods@va.gov

What to check before bidding

  • Located in United States.
  • Source notice 842e35d4355a4b14a940e27d727e5140 on SAM.gov.
  • Notice published 2 Dec 2025; Tenqual indexed it 4 Dec 2025.
  • Deadline listed as 10 Dec 2025.
  • Create a free tender alert to catch similar opportunities before the deadline pressure starts.